About: Coherent imaging of nanostructures in a low-energy scanning electron microscope with an area detector of electrons     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The contrast mechanisms based on the difference in the distribution of signal electrons recorded for every point of the surface of the bulk sample in very-low energy scanning electron microscope will be studied. The signal electrons escaping from the specimen will be processed using suitable electrostatic electron optics and imaged on a multichannel planar detector. The method will be demonstrated on the observation of diffraction contrast on clean surfaces, on the quantum size contrast on thin films with different thickness and on the contrast on semiconductors with differently doped areas. For the experiments we will use a newly designed optical system with the cathode lens for deceleration of primary beam electrons to the very-low energy, Wien filter for the deflection of signal electrons away from the optical axis and electrostatic transfer lenses. For the acquisition of signal electrons a thinned back-side directly electron-bombarded CCD will be used. (en)
  • Bude studován mechanismus vzniku kontrastu v rastrovacím elektronovém mikroskopu s velmi nízkou energií elektronů, založený na rozdílech v rozdělení signálních elektronů mezi jednotlivými body povrchu objemového vzorku. Signální elektrony vycházející ze vzorku pod různými úhly budou zpracovány vhodnou elektrostatickou elektronovou optikou a zobrazeny na mnohokanálový plošný detektor. Metoda bude ověřena pozorováním difrakčního kontrastu na čistých površích, kontrastu s dělenou amplitudou na tenkých vrstvách a kontrastu mezi různě dopovanými oblastmi polovodiče. Pro experimenty použijeme nově navržený optický systém s katodovou čočkou pro zbrždění elektronů primárního svazku na velmi nízkou energii, s Wienovým filtrem pro odklonění signálních elektronů od optické osy a s elektrostatickými transportními čočkami. Pro detekci signálních elektronů bude použit ztenčený ze zadní strany přímo elektrony bombardovaný CCD.
Title
  • Coherent imaging of nanostructures in a low-energy scanning electron microscope with an area detector of electrons (en)
  • Koherentní zobrazování nanostruktur v nízkoenergiovém rastrovacím elektronovém mikroskopu s plošným detektorem elektronů
skos:notation
  • IAA100650803
http://linked.open...avai/cep/aktivita
http://linked.open...kovaStatniPodpora
http://linked.open...ep/celkoveNaklady
http://linked.open...datumDodatniDoRIV
http://linked.open...i/cep/druhSouteze
http://linked.open...ep/duvernostUdaju
http://linked.open.../cep/fazeProjektu
http://linked.open...ai/cep/hlavniObor
http://linked.open...hodnoceniProjektu
http://linked.open...vai/cep/kategorie
http://linked.open.../cep/klicovaSlova
  • low-energy scanning electron microscope; cathode lens; Wien filtr; electron bombarded CCD (en)
http://linked.open...ep/partnetrHlavni
http://linked.open...inujicichPrijemcu
http://linked.open...cep/pocetPrijemcu
http://linked.open...ocetSpoluPrijemcu
http://linked.open.../pocetVysledkuRIV
http://linked.open...enychVysledkuVRIV
http://linked.open...lneniVMinulemRoce
http://linked.open.../prideleniPodpory
http://linked.open...iciPoslednihoRoku
http://linked.open...atUdajeProjZameru
http://linked.open.../vavai/cep/soutez
http://linked.open...usZobrazovaneFaze
http://linked.open...ai/cep/typPojektu
http://linked.open...ep/ukonceniReseni
http://linked.open.../cep/vedlejsiObor
http://linked.open...ep/zahajeniReseni
http://linked.open...jektu+dodavatelem
  • Byl rekonstruován REM s velmi nízkou energií elektronů, byly provedeny experimenty zabývající se úhlovým rozdělením signálních elektronů, byl realizován nový způsob řízení předpětí vzorku v katodové čočce, byly připraveny modifikované autoemisní katody. (cs)
  • The very-low energy SEM was newly designed, the experiments with angular distribution of the signal electrons were done, the new method of the specimen bias control in the cathode lens was implemented, the modified Schottky electron emitters were made. (en)
http://linked.open...tniCyklusProjektu
http://linked.open.../cep/klicoveSlovo
  • Wien filtr
  • cathode lens
  • low-energy scanning electron microscope
is http://linked.open...vavai/riv/projekt of
is http://linked.open...vavai/cep/projekt of
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 82 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software