| - To decrease a work of breathing in patients with COPD, ventilation with a heliox can be used. Physical characteristics of helium enable an easier gas flow through the airways compared with air. A limiting factor for using heliox in clinical practice is a high cost of helium. To minimize consumption of helium, a semi-closed circuit has been developed. As the semi-closed circuit has its own resistance, a proper evaluation of heliox effect and its deterioration due to the circuit resistance is essential. Fraction of O2 and CO2 in expired gas was measured as an indicator of change in work of breathing.
- To decrease a work of breathing in patients with COPD, ventilation with a heliox can be used. Physical characteristics of helium enable an easier gas flow through the airways compared with air. A limiting factor for using heliox in clinical practice is a high cost of helium. To minimize consumption of helium, a semi-closed circuit has been developed. As the semi-closed circuit has its own resistance, a proper evaluation of heliox effect and its deterioration due to the circuit resistance is essential. Fraction of O2 and CO2 in expired gas was measured as an indicator of change in work of breathing. (en)
|
Title
| - Optimization of a Semi-Closed Circuit for a New Way of Heliox Application in COPD Exacerbation Patients
- Optimization of a Semi-Closed Circuit for a New Way of Heliox Application in COPD Exacerbation Patients (en)
|
skos:prefLabel
| - Optimization of a Semi-Closed Circuit for a New Way of Heliox Application in COPD Exacerbation Patients
- Optimization of a Semi-Closed Circuit for a New Way of Heliox Application in COPD Exacerbation Patients (en)
|
skos:notation
| - RIV/68407700:21460/10:00169003!RIV11-GA0-21460___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(GD102/08/H018), P(NS10087), Z(MSM6840770012)
|
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68407700:21460/10:00169003
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - heliox; COPD; semi-closed circuit; airway resistance; respiratory system (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - POSTER 2010 - Proceedings of the 14th International Conference on Electrical Engineering
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Strnadová, Adéla
- Grünes, Richard
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
http://linked.open...n/vavai/riv/zamer
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| - České vysoké učení technické v Praze. Fakulta elektrotechnická
|
https://schema.org/isbn
| |
http://localhost/t...ganizacniJednotka
| |
is http://linked.open...avai/riv/vysledek
of | |