Attributes | Values |
---|
rdf:type
| |
Description
| - The production of volatile compounds from cancer cell lines in vitro has been investigated using selected ion flow tube mass spectrometry (SIFT-MS). This technique enables on-line quantitative analyses of the headspace above cell/medium cultures. This paper reports the discovery that acetaldehyde is released by the lung cancer cell lines SK-MES and CALU-1. The concentration of acetaldehyde in the headspace of the medium/cell culture was measured after 16h incubation at 37degreesC and found to be proportional to the number of cancer cells in the medium (typically 10(8)). From these data, the acetaldehyde production rates of the SK-MES cells and the CALU-1 cells in vitro are determined to be 1 x 10(6) and 1.5-3 x 10(6) molecules/cell/min, respectively. The potential value of this new technique in cell biology and in industrial cell biotechnology is discussed.
- The production of volatile compounds from cancer cell lines in vitro has been investigated using selected ion flow tube mass spectrometry (SIFT-MS). This technique enables on-line quantitative analyses of the headspace above cell/medium cultures. This paper reports the discovery that acetaldehyde is released by the lung cancer cell lines SK-MES and CALU-1. The concentration of acetaldehyde in the headspace of the medium/cell culture was measured after 16h incubation at 37degreesC and found to be proportional to the number of cancer cells in the medium (typically 10(8)). From these data, the acetaldehyde production rates of the SK-MES cells and the CALU-1 cells in vitro are determined to be 1 x 10(6) and 1.5-3 x 10(6) molecules/cell/min, respectively. The potential value of this new technique in cell biology and in industrial cell biotechnology is discussed. (en)
|
Title
| - Quantification of Acetaldehyde Released by Lung Cancer Cells in vintro Using Selected Ion Flow Tube Mass Spectrometry.
- Quantification of Acetaldehyde Released by Lung Cancer Cells in vintro Using Selected Ion Flow Tube Mass Spectrometry. (en)
|
skos:prefLabel
| - Quantification of Acetaldehyde Released by Lung Cancer Cells in vintro Using Selected Ion Flow Tube Mass Spectrometry.
- Quantification of Acetaldehyde Released by Lung Cancer Cells in vintro Using Selected Ion Flow Tube Mass Spectrometry. (en)
|
skos:notation
| - RIV/61388955:_____/03:54030040!RIV/2004/AV0/A54004/N
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(GA202/03/0827), P(GA203/02/0737), Z(AV0Z4040901)
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/61388955:_____/03:54030040
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - stage ranal-failure; trace gas-analysis; quantitative-analysis (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - GB - Spojené království Velké Británie a Severního Irska
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Rapid Communications in Mass Spectrometry
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...ocetUcastnikuAkce
| |
http://linked.open...nichUcastnikuAkce
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Smith, D.
- Španěl, Patrik
- Wang, T.
- Sule-Suso, J.
- El Haj, A.
|
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |