About: High-resolution laser interferometer with stabilized spatial position of laser beams     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • In metrology applications of laser interferometers like a scale calibration of capacitive or inductive sensors, strictly linear positioning of the measuring mirror of the interferometer is necessary. It is maintained usually by a stage, which is based on principle of linear guide ways with ball carrier bearings. But possible imperfection of guides of the travel stage can cause deviations of the mirror plane from the right angle to the axis of traveling. Mentioned angle deviations lead to distortion of interference fringes in the output of the interferometer and by other words it causes non-linearity of the interferometer scale. We present a method, which eliminates the problem by a special configuration of the interferometer and continual monitoring of spatial position of beams in the interferometer when the mirror is positioned. It works with condition that the mirror can be slightly tilted by piezoelectric actuators in servo-loop mode with respect to detected spatial position.
  • In metrology applications of laser interferometers like a scale calibration of capacitive or inductive sensors, strictly linear positioning of the measuring mirror of the interferometer is necessary. It is maintained usually by a stage, which is based on principle of linear guide ways with ball carrier bearings. But possible imperfection of guides of the travel stage can cause deviations of the mirror plane from the right angle to the axis of traveling. Mentioned angle deviations lead to distortion of interference fringes in the output of the interferometer and by other words it causes non-linearity of the interferometer scale. We present a method, which eliminates the problem by a special configuration of the interferometer and continual monitoring of spatial position of beams in the interferometer when the mirror is positioned. It works with condition that the mirror can be slightly tilted by piezoelectric actuators in servo-loop mode with respect to detected spatial position. (en)
  • V metrologických aplikacích, ve kterých se provádí kalibrace kapacitních či indukčnostních snímačů, je nutné zaručit přísně rovnoběžné polohování měřicího zrcadla interferometru. Toto se zajišťuje zejména polohovacím stolkem jehož posuv využívá přesných lineárních vedení na bázi kuličkových převodů. Přesto případné osové odchylky těchto vedení mohou způsobit nepatrný náklon roviny zrcadla od kolmice k ose vedení. Tato, i velmi nepatrná úhlová odchylka však může způsobit zkreslení průběhu interferenčního proužku na výstupu interferometru, což v konečném důsledku způsobí nelinearitu stupnice interferometru. Představujeme metodu, která eliminuje uvedený problém zvláštním uspořádáním laserového interferometru a kontinuálním sledováním prostorové pozice laserových svazků, které dopadají na měřicí zrcadlo interferometru. V případě, že detektory indikují odchylku od stanoveného místa dopadu, pomocí piezoelektrických měničů je měřicí zrcadlo naklopeno do správné polohy. (cs)
Title
  • High-resolution laser interferometer with stabilized spatial position of laser beams
  • Přesný laserový interferometr s prostorovou stabilizací polohy laserových svazků (cs)
  • High-resolution laser interferometer with stabilized spatial position of laser beams (en)
skos:prefLabel
  • High-resolution laser interferometer with stabilized spatial position of laser beams
  • Přesný laserový interferometr s prostorovou stabilizací polohy laserových svazků (cs)
  • High-resolution laser interferometer with stabilized spatial position of laser beams (en)
skos:notation
  • RIV/68081731:_____/08:00316633!RIV09-AV0-68081731
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(2A-1TP1/127), P(2A-3TP1/113), P(2C06012), P(FT-TA3/133), P(GA102/07/1179), P(IAA200650504), P(LC06007), Z(AV0Z20650511)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 370140
http://linked.open...ai/riv/idVysledku
  • RIV/68081731:_____/08:00316633
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • high resolution interferometry; nanometrology (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [F446CB7E9B9F]
http://linked.open...v/mistoKonaniAkce
  • Ilmenau
http://linked.open...i/riv/mistoVydani
  • llmenau
http://linked.open...i/riv/nazevZdroje
  • ICPM 2008 - International Conference on Precision Measurement
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Buchta, Zdeněk
  • Lazar, Josef
  • Číp, Ondřej
  • Čížek, Martin
  • Šmíd, Radek
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Technische Universität llmenau
https://schema.org/isbn
  • 978-3-938843-38-3
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software