| - Long-distance electrical signals generated in locally stimulated plants are linked with systemic physiological responses. The propagation of electrical signal through a plant can be measured by multiple electrodes attached to different sites of a plant body. As this signal has to be measured with the sensitivity of tens of microvolts, it can be easily disturbed by power-line hums or external electromagnetic fields. These disturbances can mimic the action potentials generated by a plant. In this work, we present a brief summary of various experimental approaches to the measurement of surface electrical potential (SEP) on a plant and a description of our multi-channel device for the SEP measurement. The main advantages of our measuring system are galvanic separation of the measuring unit, resulting in the elimination of power-line disturbances, and simple and stable contact of Ag/AgCl-peletted electrodes with the plant surface, facilitated by an ordinary gel used in human electrocardiography.
- Long-distance electrical signals generated in locally stimulated plants are linked with systemic physiological responses. The propagation of electrical signal through a plant can be measured by multiple electrodes attached to different sites of a plant body. As this signal has to be measured with the sensitivity of tens of microvolts, it can be easily disturbed by power-line hums or external electromagnetic fields. These disturbances can mimic the action potentials generated by a plant. In this work, we present a brief summary of various experimental approaches to the measurement of surface electrical potential (SEP) on a plant and a description of our multi-channel device for the SEP measurement. The main advantages of our measuring system are galvanic separation of the measuring unit, resulting in the elimination of power-line disturbances, and simple and stable contact of Ag/AgCl-peletted electrodes with the plant surface, facilitated by an ordinary gel used in human electrocardiography. (en)
|
Title
| - A low-noise multi-channel device for the monitoring of systemic electrical signal propagation in plants
- A low-noise multi-channel device for the monitoring of systemic electrical signal propagation in plants (en)
|
skos:prefLabel
| - A low-noise multi-channel device for the monitoring of systemic electrical signal propagation in plants
- A low-noise multi-channel device for the monitoring of systemic electrical signal propagation in plants (en)
|
skos:notation
| - RIV/61989592:15310/10:10212197!RIV11-MSM-15310___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/61989592:15310/10:10212197
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - action potential, local wounding, systemic response, variation potential (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Ilík, Petr
- Hlaváčková, Vladimíra
- Nauš, Jan
- Krchňák, Pavel
|
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |
http://localhost/t...ganizacniJednotka
| |
is http://linked.open...avai/riv/vysledek
of | |