  • Objectives: The aim is to define conditions for exact measurement of urethral pressure profile, to prepare an aparatus and fabricate an artificial urethra for testing measuring catethers. To examine it's qualities by experiment. Methods: We designed a measuring appliance and a specialized software for measuring and evaluating. An experimental phantom of urethra, made from a part of bull's urethra, was used for testing of measurement's validity with use of different measuring catethers. Measurements were 10x repeated within the same position of the catether. Reproducibility of the measurement and stability of the experimental model was tested. Results: Measuring urethra and experimental phantom of urethra succeeded, it was possible to make well reproducible measurements with different measuring catethers and to evaluate their metrologic abilities and limits. Results of our measurements confirmed appointed theoretical conditions of the measurement. Conclusion: Measurements proved
  • Objectives: The aim is to define conditions for exact measurement of urethral pressure profile, to prepare an aparatus and fabricate an artificial urethra for testing measuring catethers. To examine it's qualities by experiment. Methods: We designed a measuring appliance and a specialized software for measuring and evaluating. An experimental phantom of urethra, made from a part of bull's urethra, was used for testing of measurement's validity with use of different measuring catethers. Measurements were 10x repeated within the same position of the catether. Reproducibility of the measurement and stability of the experimental model was tested. Results: Measuring urethra and experimental phantom of urethra succeeded, it was possible to make well reproducible measurements with different measuring catethers and to evaluate their metrologic abilities and limits. Results of our measurements confirmed appointed theoretical conditions of the measurement. Conclusion: Measurements proved (en)
  • Cíl: Definovat podmínky k přesnému měření uretrálního tlakového profilu avytvoření arteficiální uretry protestování měřících katetrů, k testování jejich kvality experimentem. Metoda: Navrhli jsme měřící zařízení a specializovaný měřící software. experimentální fantom uretry z býčí uretry byl použit pro měření s různými katetry. Výsledky: Měření s různými katetry a jejich metrologické vlastnosti zjištilo jejich metrologic vlastnosti a limity. Závěr: Měření prokázalo, že možné simulovat podmínky podobné fyziologickým podmínkám a je možné testovat metrologické vlastnosti při profilometrii uretry (cs)
Title
  • Possibilities of experimental verification of the validity of urethral pressure rofilometry
  • Možnosti experimentálního ověření validity uretrální profilometrie (cs)
  • Possibilities of experimental verification of the validity of urethral pressure rofilometry (en)
skos:prefLabel
  • Possibilities of experimental verification of the validity of urethral pressure rofilometry
  • Možnosti experimentálního ověření validity uretrální profilometrie (cs)
  • Possibilities of experimental verification of the validity of urethral pressure rofilometry (en)
skos:notation
  • RIV/61989592:15110/06:00003117!RIV07-MZ0-15110___
http://linked.open.../vavai/riv/strany
  • 345-348
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA106/04/0201), P(NR7840)
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 493206
http://linked.open...ai/riv/idVysledku
  • RIV/61989592:15110/06:00003117
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Urethral pressure profile; Profilometry; Experimental measurement (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [8240284CDBC4]
http://linked.open...i/riv/nazevZdroje
  • Biomedical Papers
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 150
http://linked.open...iv/tvurceVysledku
  • Rosenberg, Jan
  • Záťura, František
issn
  • 1213-8118
number of pages
http://localhost/t...ganizacniJednotka
  • 15110
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software