About: Separation of oxalate, formate and glycolate in human body fluid samples by capillary electrophoresis with contactless conductometric detection     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A new method for rapid determination of toxic metabolites after methanol and ethylene glycol intoxication - oxalate, formate and glycolate in various body fluid samples (blood serum, saliva, urine, exhaled breath condensate) by capillary electrophoresis with contactless conductometric detection was developed. A selective separation of the three target analytes from other constituents present in the analyzed biological matrices was achieved in less than 6 min in a fused silica capillary of 25 mu m I.D. using an electrolyte comprising 50 mM L-histidine and 50 mM 2-(N-morpholino)ethanesulfonic acid at pH 6.1. The only sample preparation was dilution with deionized water. The limits of detection were 0.4, 0.6 and 1.3 mu M and limits of quantitation 1.3, 1.9 and 4.2 mu M for oxalate, formate and glycolate, respectively. The method provides a simple and rapid diagnostic test in suspected intoxication and is able to distinguish the ingested liquid, based on its metabolite trace.
  • A new method for rapid determination of toxic metabolites after methanol and ethylene glycol intoxication - oxalate, formate and glycolate in various body fluid samples (blood serum, saliva, urine, exhaled breath condensate) by capillary electrophoresis with contactless conductometric detection was developed. A selective separation of the three target analytes from other constituents present in the analyzed biological matrices was achieved in less than 6 min in a fused silica capillary of 25 mu m I.D. using an electrolyte comprising 50 mM L-histidine and 50 mM 2-(N-morpholino)ethanesulfonic acid at pH 6.1. The only sample preparation was dilution with deionized water. The limits of detection were 0.4, 0.6 and 1.3 mu M and limits of quantitation 1.3, 1.9 and 4.2 mu M for oxalate, formate and glycolate, respectively. The method provides a simple and rapid diagnostic test in suspected intoxication and is able to distinguish the ingested liquid, based on its metabolite trace. (en)
Title
  • Separation of oxalate, formate and glycolate in human body fluid samples by capillary electrophoresis with contactless conductometric detection
  • Separation of oxalate, formate and glycolate in human body fluid samples by capillary electrophoresis with contactless conductometric detection (en)
skos:prefLabel
  • Separation of oxalate, formate and glycolate in human body fluid samples by capillary electrophoresis with contactless conductometric detection
  • Separation of oxalate, formate and glycolate in human body fluid samples by capillary electrophoresis with contactless conductometric detection (en)
skos:notation
  • RIV/00216224:14310/14:00073642!RIV15-MSM-14310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.1.00/02.0068), P(GA13-21919S), S
http://linked.open...iv/cisloPeriodika
  • January
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 44520
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14310/14:00073642
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Capillary electrophoresis; Contactless conductivity detection; Toxic metabolites; Methanol intoxication; Ethylene glycol intoxication; Body fluid samples (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [785BE76E990F]
http://linked.open...i/riv/nazevZdroje
  • Journal of Chromatography A
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 1325
http://linked.open...iv/tvurceVysledku
  • Bittová, Miroslava
  • Foret, František
  • Kubáň, Petr
  • Ďurč, Pavol
http://linked.open...ain/vavai/riv/wos
  • 000330256200031
issn
  • 0021-9673
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.chroma.2013.12.039
http://localhost/t...ganizacniJednotka
  • 14310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 41 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software