Attributes | Values |
---|
rdf:type
| |
Description
| - The piezoelectric quartz crystal operating in the active mode was used as a transducer for construction of immunosensors for determination polychlorinated biphenyls(PCB). An apparatus for flow-through measurements with piezosensors in pure organic phase was constructed. The anti-PCB polyclonal antibody was immobilized in an oriented way via protein A on a smooth gold surface. The antibody high cross-reactivity for 2,4,4'-trichlorobiphenyl, 4,4'-dichlorobiphenyl and 3,3,4,4'-tetrachlorbiphenyl allowed for a specific determination of these congeners in samples. PCBs were determined either directly or using competition with a tracer, synthesized from polystyrene particles by covalent attachment of 4,4'-dichlorobiphenyl (DCB). The direct piezoelectric immunosensor operated in phosphate buffer with 5% dimethylsulphoxide. It was possible to detect coplanar PCBs in the range 1-50ppm. A higher detection limit is compensated here by the low cost and short time of analysis, below 20 min.
- The piezoelectric quartz crystal operating in the active mode was used as a transducer for construction of immunosensors for determination polychlorinated biphenyls(PCB). An apparatus for flow-through measurements with piezosensors in pure organic phase was constructed. The anti-PCB polyclonal antibody was immobilized in an oriented way via protein A on a smooth gold surface. The antibody high cross-reactivity for 2,4,4'-trichlorobiphenyl, 4,4'-dichlorobiphenyl and 3,3,4,4'-tetrachlorbiphenyl allowed for a specific determination of these congeners in samples. PCBs were determined either directly or using competition with a tracer, synthesized from polystyrene particles by covalent attachment of 4,4'-dichlorobiphenyl (DCB). The direct piezoelectric immunosensor operated in phosphate buffer with 5% dimethylsulphoxide. It was possible to detect coplanar PCBs in the range 1-50ppm. A higher detection limit is compensated here by the low cost and short time of analysis, below 20 min. (en)
|
Title
| - Piezoelectric immunosensors for polychlorinated biphenyls operating in aqueous and organic phases
- Piezoelectric immunosensors for polychlorinated biphenyls operating in aqueous and organic phases (en)
|
skos:prefLabel
| - Piezoelectric immunosensors for polychlorinated biphenyls operating in aqueous and organic phases
- Piezoelectric immunosensors for polychlorinated biphenyls operating in aqueous and organic phases (en)
|
skos:notation
| - RIV/00216224:14310/06:00016802!RIV10-MSM-14310___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(OBVTUO2003001), Z(MSM0021622413)
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216224:14310/06:00016802
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Biosensor; Toluene; Quartz crystal nanobalance (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Sensors and Actuators B Chemical
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Skládal, Petr
- Přibyl, Jan
- Hepel, Maria
|
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |
http://localhost/t...ganizacniJednotka
| |
is http://linked.open...avai/riv/vysledek
of | |