About: Bell-shaped extraction device assisted liquid-liquid microextraction technique and its optimization using response-surface methodology     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • We have developed a new microextraction technique for equilibrium, non-exhaustive analyte pre-concentration from aqueous solutions into organic solvents lighter than water. The key point of the method is application of specially designed and optimized bell-shaped extraction device, BSED. The technique has been tested and applied to the preconcentration of selected volatile and semi volatile compounds which were determined by gas chromatography/mass spectrometry in spiked water samples. The significant parameters of the extraction have been found using chemometric procedures and these parameters were optimized using the central composite design (CCD) for two solvents. The analyte preconcentration factors were in a range from 8.3 to 161.8 (repeatability from 7 to 14%) for heptane, and 50.0-105.0 (repeatability from 0 to 5%) for tert-butyl acetate. The reproducibility of the technique was within 1-8%. The values of limits of detection and determination were 0.1-3.3 ng mL(-1) for heptane and 0.3-10.7 ngmL(-1) for tert-butyl acetate. The new microextraction technique has been found to be a cheap, simple and flexible alternative to the common procedures, such as SPME or LLME. This BSED-LLME technique can also be combined with other separation methods, e.g.. HPLC or CE.
  • We have developed a new microextraction technique for equilibrium, non-exhaustive analyte pre-concentration from aqueous solutions into organic solvents lighter than water. The key point of the method is application of specially designed and optimized bell-shaped extraction device, BSED. The technique has been tested and applied to the preconcentration of selected volatile and semi volatile compounds which were determined by gas chromatography/mass spectrometry in spiked water samples. The significant parameters of the extraction have been found using chemometric procedures and these parameters were optimized using the central composite design (CCD) for two solvents. The analyte preconcentration factors were in a range from 8.3 to 161.8 (repeatability from 7 to 14%) for heptane, and 50.0-105.0 (repeatability from 0 to 5%) for tert-butyl acetate. The reproducibility of the technique was within 1-8%. The values of limits of detection and determination were 0.1-3.3 ng mL(-1) for heptane and 0.3-10.7 ngmL(-1) for tert-butyl acetate. The new microextraction technique has been found to be a cheap, simple and flexible alternative to the common procedures, such as SPME or LLME. This BSED-LLME technique can also be combined with other separation methods, e.g.. HPLC or CE. (en)
Title
  • Bell-shaped extraction device assisted liquid-liquid microextraction technique and its optimization using response-surface methodology
  • Bell-shaped extraction device assisted liquid-liquid microextraction technique and its optimization using response-surface methodology (en)
skos:prefLabel
  • Bell-shaped extraction device assisted liquid-liquid microextraction technique and its optimization using response-surface methodology
  • Bell-shaped extraction device assisted liquid-liquid microextraction technique and its optimization using response-surface methodology (en)
skos:notation
  • RIV/00216208:11310/12:10126438!RIV13-MSM-11310___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, S, Z(MSM0021620857)
http://linked.open...iv/cisloPeriodika
  • March
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 124676
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11310/12:10126438
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Gas chromatography; Response-surface methodology; Liquid-liquid microextraction (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [7C3FDD74FF87]
http://linked.open...i/riv/nazevZdroje
  • Journal of Chromatography A
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 1230
http://linked.open...iv/tvurceVysledku
  • Čabala, Radomír
  • Bursová, Miroslava
http://linked.open...ain/vavai/riv/wos
  • 000301959700004
http://linked.open...n/vavai/riv/zamer
issn
  • 0021-9673
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.chroma.2012.01.069
http://localhost/t...ganizacniJednotka
  • 11310
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software