About: How to address the sample preparation of hydrophilic compounds: Determination of entecavir in plasma and plasma ultrafiltrate with novel extraction sorbents     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Two fast, simple, selective and economical sample preparation methods for the determination of entecavir in biological materials available at low amounts are reported. The choice of optimal extraction techniques was performed with regard to analyte hydrophilicity, sample volumes, selectivity, method recovery and rapidity. The compatibility of the eluate with the hydrophilic interaction chromatography (HILIC) mobile phase was crucial to allow the elimination of the evaporation and reconstitution steps and to obtain acceptable peak shapes. Different types of sorbents were employed for the extraction of two biological materials (plasma and plasma ultrafiltrate). The mixed-mode polymeric sorbent MCX was chosen as a suitable one for the solid phase extraction (SPE) of plasma samples. The analytes were eluted with 1 ml of the mixture of 5% ammonium hydroxide in ACN:water (95:5). Protein precipitation (PP) with 1 ml of ACN was used to remove proteins from 500 RI of plasma sample prior to SPE extraction. The microextraction by packed sorbent (MEPS) was employed for the cleaning up of plasma ultrafiltrate samples due to very small volumes available for the analysis. MEPS implemented a novel sorbent based on porous graphitic carbon, semi-automatic analytical syringe and a small volume of sample (50 mu l). The elution step was performed using 100 mu l of the mixture of 5 mM ammonium acetate pH 4.0:ACN (25:75). The MEPS eluate was fully compatible with HILIC mobile phase subsequently used for the analysis of entecavir, unlike SPE eluate, which had to be evaporated and reconstituted in mobile phase.
  • Two fast, simple, selective and economical sample preparation methods for the determination of entecavir in biological materials available at low amounts are reported. The choice of optimal extraction techniques was performed with regard to analyte hydrophilicity, sample volumes, selectivity, method recovery and rapidity. The compatibility of the eluate with the hydrophilic interaction chromatography (HILIC) mobile phase was crucial to allow the elimination of the evaporation and reconstitution steps and to obtain acceptable peak shapes. Different types of sorbents were employed for the extraction of two biological materials (plasma and plasma ultrafiltrate). The mixed-mode polymeric sorbent MCX was chosen as a suitable one for the solid phase extraction (SPE) of plasma samples. The analytes were eluted with 1 ml of the mixture of 5% ammonium hydroxide in ACN:water (95:5). Protein precipitation (PP) with 1 ml of ACN was used to remove proteins from 500 RI of plasma sample prior to SPE extraction. The microextraction by packed sorbent (MEPS) was employed for the cleaning up of plasma ultrafiltrate samples due to very small volumes available for the analysis. MEPS implemented a novel sorbent based on porous graphitic carbon, semi-automatic analytical syringe and a small volume of sample (50 mu l). The elution step was performed using 100 mu l of the mixture of 5 mM ammonium acetate pH 4.0:ACN (25:75). The MEPS eluate was fully compatible with HILIC mobile phase subsequently used for the analysis of entecavir, unlike SPE eluate, which had to be evaporated and reconstituted in mobile phase. (en)
Title
  • How to address the sample preparation of hydrophilic compounds: Determination of entecavir in plasma and plasma ultrafiltrate with novel extraction sorbents
  • How to address the sample preparation of hydrophilic compounds: Determination of entecavir in plasma and plasma ultrafiltrate with novel extraction sorbents (en)
skos:prefLabel
  • How to address the sample preparation of hydrophilic compounds: Determination of entecavir in plasma and plasma ultrafiltrate with novel extraction sorbents
  • How to address the sample preparation of hydrophilic compounds: Determination of entecavir in plasma and plasma ultrafiltrate with novel extraction sorbents (en)
skos:notation
  • RIV/00216208:11160/14:10146060!RIV15-MSM-11160___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(EE2.3.30.0022), S
http://linked.open...iv/cisloPeriodika
  • January
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 19798
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/14:10146060
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Hydrophilic compounds; Sample preparation; Porous graphitic carbon; MEPS; Antivirals (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [0D0937C2FBF0]
http://linked.open...i/riv/nazevZdroje
  • Journal of Pharmaceutical and Biomedical Analysis
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 88
http://linked.open...iv/tvurceVysledku
  • Solich, Petr
  • Nováková, Lucie
  • Trejtnar, František
  • Vlčková, Hana
  • Gottvald, Tomáš
  • Janák, Jaroslav
http://linked.open...ain/vavai/riv/wos
  • 000329532800045
issn
  • 0731-7085
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.jpba.2013.08.034
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 22 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software