| - We compared two methods of evaluation of capillary supply of individual skeletal muscle fibers, the traditional one using 2D images of thin transverse sections by the number of capillary profiles around a fiber (CAF) and the 3D approach where the mean length of capillaries around individual muscle fibers per fiber length (Lcap/Lfib) is measured from 3D images acquired by confocal microscopy. In models we showed that Lcap/Lfib was sensitive to different arrangements of capillaries, while CAF underestimated capillarization since it could not detect the increased length of capillary bed. In true muscle samples, we detected statistically significant differences in the capillary supply of control and denervated rat soleus muscles by both 2D and 3D methods. Lcap/Lfib was larger than CAF in control muscles reflecting their more complicated capillary bed
- We compared two methods of evaluation of capillary supply of individual skeletal muscle fibers, the traditional one using 2D images of thin transverse sections by the number of capillary profiles around a fiber (CAF) and the 3D approach where the mean length of capillaries around individual muscle fibers per fiber length (Lcap/Lfib) is measured from 3D images acquired by confocal microscopy. In models we showed that Lcap/Lfib was sensitive to different arrangements of capillaries, while CAF underestimated capillarization since it could not detect the increased length of capillary bed. In true muscle samples, we detected statistically significant differences in the capillary supply of control and denervated rat soleus muscles by both 2D and 3D methods. Lcap/Lfib was larger than CAF in control muscles reflecting their more complicated capillary bed (en)
|
Title
| - The estimation error of skeletal muscle capillary supply is significantly reduced by 3D Metod
- The estimation error of skeletal muscle capillary supply is significantly reduced by 3D Metod (en)
|
skos:prefLabel
| - The estimation error of skeletal muscle capillary supply is significantly reduced by 3D Metod
- The estimation error of skeletal muscle capillary supply is significantly reduced by 3D Metod (en)
|
skos:notation
| - RIV/67985823:_____/10:00341849!RIV11-GA0-67985823
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(GD204/09/H084), P(LC06063), P(MEB090910), Z(AV0Z50110509)
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/67985823:_____/10:00341849
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - confocal microscopy; capillaries; length measurement (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - US - Spojené státy americké
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Eržen, I.
- Janáček, Jiří
- Kubínová, Lucie
- Vyhnal, Aleš
- Čebašek, V.
- Ribarič, S.
|
http://linked.open...ain/vavai/riv/wos
| |
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |
is http://linked.open...avai/riv/vysledek
of | |