About: An electric focusing preconcentration and in-time monitoring of element composition of air aerosols by atomic emission spectroscopy     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • An attention focused on the role of aerosols in climate and atmospheric chemistry is shifting in the light of the terrorism danger as a threat of human being. The demand for %22real time%22 aerosol composition measurement has never been higher. Although there has been made some progress in mass spectrometric (MS) identification of biological material and also others single particle MS studies exist, an electric focusing preconcentration and in-time monitoring of element composition of air aerosols by atomic emission spectroscopy is promising way in regulatory, epidemiological and toxicological applications and more routine measurements in on-coming time period. The aim is to study an electric focusing preconcentration and in-time monitoring of element (heavy metal) composition of air aerosols by atomic emission spectroscopy. In addition the electric focusing preconcentration could be used in the course of determination of biological materials in air in future. (en)
  • Do nedávné doby byla věnována pozornost aerosolům s cílem vyjasnit zejména jejich vztah ke změnám klimatu a jejich postavení v chemii atmosféry. Od zářijových událostí roku 2001 se k těmto tématů přidalo téma teroristického nebezpečí. Proto se v současnosti klade takový důraz na analýzu aerosolů, která má probíhat v reálném čase. V současnosti existují zařízení, na principu MS techniky, umožňující identifikaci biologického materiálu v ovzduší stejně jako bylo MS technik použito při analýze jednotlivých částic aerosolu v reálném čase. Tato zařízení jsou však pro nejširší použití nevhodná. Podle našeho názoru elektrická fokusační technika a její spojení s atomovou emisní spektrometrií je nadějnou metodou použitelnou při epidemiologických a toxikologických studiích a dalších rutinních měřeních, při kterých je nutné identifikovat jednotlivé zdroje aerosolů. Zvládnutí principu kontinuální elektrické fokusace aerosolu bude využitelné i při stanovaní obsahu biologického materiálu v ovzduší.
Title
  • An electric focusing preconcentration and in-time monitoring of element composition of air aerosols by atomic emission spectroscopy (en)
  • Elektrická fokusační předkoncentrace a kontinuální prvková analýza aerosolů atomovou emisní spektrometrií
skos:notation
  • IAA400310505
http://linked.open...avai/cep/aktivita
http://linked.open...kovaStatniPodpora
http://linked.open...ep/celkoveNaklady
http://linked.open...datumDodatniDoRIV
http://linked.open...i/cep/druhSouteze
http://linked.open...ep/duvernostUdaju
http://linked.open.../cep/fazeProjektu
http://linked.open...ai/cep/hlavniObor
http://linked.open...hodnoceniProjektu
http://linked.open...vai/cep/kategorie
http://linked.open.../cep/klicovaSlova
  • electrostatic focussing; development of electrostatic precipitator; preconcentration of aerosol particles; continuous analysis; atomic emission detection; elemental composition of aerosols; in time monitoring (en)
http://linked.open...ep/partnetrHlavni
http://linked.open...inujicichPrijemcu
http://linked.open...cep/pocetPrijemcu
http://linked.open...ocetSpoluPrijemcu
http://linked.open.../pocetVysledkuRIV
http://linked.open...enychVysledkuVRIV
http://linked.open...lneniVMinulemRoce
http://linked.open.../prideleniPodpory
http://linked.open...iciPoslednihoRoku
http://linked.open...atUdajeProjZameru
http://linked.open.../vavai/cep/soutez
http://linked.open...usZobrazovaneFaze
http://linked.open...ai/cep/typPojektu
http://linked.open...ep/ukonceniReseni
http://linked.open.../cep/vedlejsiObor
http://linked.open...ep/zahajeniReseni
http://linked.open...jektu+dodavatelem
  • Based on computer simulation of electrostatic forces and flow patterns of particles in air, preconcentration device was constructed for microwave induced plasma detection of elemental composition of PM 0.3-1 µm airborn particles by emission spectrometry (en)
  • Na základě počítačových simulací elektrostatických interakcí částic v proudícím vzduchu bylo navrženo a zkonstruováno nové zařízení ke zkoncentrování aerosolových částic PM 0.3-1 µm pro stanovení jejich elementárního složení optickou emisní spektrometrií (cs)
http://linked.open...tniCyklusProjektu
http://linked.open.../cep/klicoveSlovo
  • atomic emission detection
  • continuous analysis
  • development of electrostatic precipitator
  • elemental composition of aerosols
  • preconcentration of aerosol particles
  • electrostatic focussing
is http://linked.open...vavai/riv/projekt of
is http://linked.open...vavai/cep/projekt of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 117 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software