About: Quantification of trace element species in human serum fractions by liquid chromatography and inductively coupled plasma mass spectrometry     Goto   Sponge   Distinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The on-line coupling of LC and ICP-MS was used for fractionation and detection of species of Cu, Fe, I, Se and Zn in human serum. It has been shown that anion exchange chromatography proved better separation capability (both intra- and inter- element) than size exclusion chromatography. The mobile phases for ion exchange chromatography consisted of Tris-HNO3 buffer and ammonium salt (nitrate, acetate or formate). Formate was found to be the best mobile phase counter ion, which enables good chromatographic separation and is acceptable for mass spectrometer too. The quantitative evaluation of elements' concentrations adherent to individual fractions was performed by peak's area normalisation method. The repeatability of results ranges from 3 to 15 % (depending on the element fraction level) and represents the main part of result uncertainty. Accuracy of Cu and Zn fractions determination was confirmed by comparison with isotope dilution technique.
  • The on-line coupling of LC and ICP-MS was used for fractionation and detection of species of Cu, Fe, I, Se and Zn in human serum. It has been shown that anion exchange chromatography proved better separation capability (both intra- and inter- element) than size exclusion chromatography. The mobile phases for ion exchange chromatography consisted of Tris-HNO3 buffer and ammonium salt (nitrate, acetate or formate). Formate was found to be the best mobile phase counter ion, which enables good chromatographic separation and is acceptable for mass spectrometer too. The quantitative evaluation of elements' concentrations adherent to individual fractions was performed by peak's area normalisation method. The repeatability of results ranges from 3 to 15 % (depending on the element fraction level) and represents the main part of result uncertainty. Accuracy of Cu and Zn fractions determination was confirmed by comparison with isotope dilution technique. (en)
  • Frakcionace specií Cu, Fe, I, Se a Zn v lidském séru byla provedena pomocí on-line spojení kapalinové chromatografie a pomocí hmotnostní spekrometrie s indukčně vázaným plazmatem. Iontově výměnná chromatografie se ukázala jako metoda vhodnější než gelová chromatografie. Jako nejvhodnější mobilní fáze byl použit mravenčanový pufr. Kvantitativní vyhodnocení obsahu kovů v jednotlivých bylo provedeno pomocí normalizace píků, opakovatelnost byla 3 - 15 %. Správnost stanovení Cu a Zn byla ověřena pomocí izotopového zřeďování. (cs)
Title
  • Quantification of trace element species in human serum fractions by liquid chromatography and inductively coupled plasma mass spectrometry
  • Quantification of trace element species in human serum fractions by liquid chromatography and inductively coupled plasma mass spectrometry (en)
  • Kvantifikace specií stopových prvků v lidském séru pomocí kapalinové chromatografie a hmotnostní spektrometrie s indukčně vázaným plazmatem (cs)
skos:prefLabel
  • Quantification of trace element species in human serum fractions by liquid chromatography and inductively coupled plasma mass spectrometry
  • Quantification of trace element species in human serum fractions by liquid chromatography and inductively coupled plasma mass spectrometry (en)
  • Kvantifikace specií stopových prvků v lidském séru pomocí kapalinové chromatografie a hmotnostní spektrometrie s indukčně vázaným plazmatem (cs)
skos:notation
  • RIV/60461373:22340/07:00019318!RIV08-MSM-22340___
http://linked.open.../vavai/riv/strany
  • 5-14
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM6046137305), Z(MSM6046137307)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 446147
http://linked.open...ai/riv/idVysledku
  • RIV/60461373:22340/07:00019318
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Serum; Trace elements; Metalloproteins; Liquid chromatography; Inductively coupled plasma mass spectrometry (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [6FB76861EF3B]
http://linked.open...i/riv/nazevZdroje
  • Applied Organometallic Chemistry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 21
http://linked.open...iv/tvurceVysledku
  • Kodíček, Milan
  • Koplík, Richard
  • Mestek, Oto
  • Zima, Tomáš
  • Komínková, Jana
http://linked.open...n/vavai/riv/zamer
issn
  • 0268-2605
number of pages
http://localhost/t...ganizacniJednotka
  • 22340
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software