About: A Comparison of AE Sensor Calibration Methods     Goto   Sponge   Distinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The paper reviews the background of the primary calibration of acoustic emission (AE) sensors and the determination of uncertainty in the calibration. The main sources of uncertainty in practical usage of calibration results are discussed. The comparison of the results of the reciprocity primary calibration, step-force and reciprocity calibration with broadband-pulse excitation method is presented. The shape of calibration characteristics corresponds well up to 300 kHz. The calculation of the uncertainty in all the calibration methods is described. The problem of propagation of uncertainty in the fast Fourier algorithm was solved. Uncertainty of measurement by primary calibration is determined and the influence of selected sources of uncertainty for each used method of calibration is presented and practically measured results are discussed. Piezoelectric AE sensor PAC UT1000 was used as the sensor under test. The big influence on uncertainty in calibrations was the influence of remounting sensors and
  • The paper reviews the background of the primary calibration of acoustic emission (AE) sensors and the determination of uncertainty in the calibration. The main sources of uncertainty in practical usage of calibration results are discussed. The comparison of the results of the reciprocity primary calibration, step-force and reciprocity calibration with broadband-pulse excitation method is presented. The shape of calibration characteristics corresponds well up to 300 kHz. The calculation of the uncertainty in all the calibration methods is described. The problem of propagation of uncertainty in the fast Fourier algorithm was solved. Uncertainty of measurement by primary calibration is determined and the influence of selected sources of uncertainty for each used method of calibration is presented and practically measured results are discussed. Piezoelectric AE sensor PAC UT1000 was used as the sensor under test. The big influence on uncertainty in calibrations was the influence of remounting sensors and (en)
Title
  • A Comparison of AE Sensor Calibration Methods
  • A Comparison of AE Sensor Calibration Methods (en)
skos:prefLabel
  • A Comparison of AE Sensor Calibration Methods
  • A Comparison of AE Sensor Calibration Methods (en)
skos:notation
  • RIV/00216305:26220/08:PU80701!RIV10-MSM-26220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA101/06/1689), Z(MSM0021630529)
http://linked.open...iv/cisloPeriodika
  • 26
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 354094
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/08:PU80701
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • AE sensor calibration, Reciprocity calibration, Step force calibration, Uncertainty (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [1899B5A64784]
http://linked.open...i/riv/nazevZdroje
  • Journal of Acoustic Emission
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 2008
http://linked.open...iv/tvurceVysledku
  • Beneš, Petr
  • Keprt, Jiří
http://linked.open...n/vavai/riv/zamer
issn
  • 0730-0050
number of pages
http://localhost/t...ganizacniJednotka
  • 26220
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 22 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software