"RIV/68407700:21670/11:00178253!RIV12-MSM-21670___" . "1" . . . . "Evaluation of strain field in microstructures using micro-CT and digital volume correlation" . "Journal of Instrumentation" . "Evaluation of strain field in microstructures using micro-CT and digital volume correlation"@en . . . "10.1088/1748-0221/6/01/C01039" . "IT - Italsk\u00E1 republika" . "198366" . "000291345600044" . . "5"^^ . . . . "X-ray digital micro-tomography was employed for precise strain measurement which is essential for evaluation of the experiments with small samples of trabecular bone. X-ray Digital Volumetric Correlation (DVC) method was used to identify the three-dimensional strain field in loaded complex microstructure. DVC relies on tracking selected sample points within the three-dimensional image data throughout the sequence of captured projections. In this study an improved DVC method is applied for evaluation of the strain field in trabecular bone sample subjected to compressive loading. The deformed sample was tomographically scanned using micro-focus X-ray tube and the single-photon counting silicon pixel detector Medipix2." . . "Evaluation of strain field in microstructures using micro-CT and digital volume correlation"@en . "Jirou\u0161ek, O." . "Jandejsek, Ivan" . "6" . "Vav\u0159\u00EDk, Daniel" . . "RIV/68407700:21670/11:00178253" . "[2FF9D52DEE4A]" . . "1748-0221" . . "http://iopscience.iop.org/1748-0221/6/01/C01039" . . . . "21670" . "X-ray digital micro-tomography was employed for precise strain measurement which is essential for evaluation of the experiments with small samples of trabecular bone. X-ray Digital Volumetric Correlation (DVC) method was used to identify the three-dimensional strain field in loaded complex microstructure. DVC relies on tracking selected sample points within the three-dimensional image data throughout the sequence of captured projections. In this study an improved DVC method is applied for evaluation of the strain field in trabecular bone sample subjected to compressive loading. The deformed sample was tomographically scanned using micro-focus X-ray tube and the single-photon counting silicon pixel detector Medipix2."@en . . . "Evaluation of strain field in microstructures using micro-CT and digital volume correlation" . "P(GAP105/10/2305), S, Z(AV0Z20710524), Z(MSM6840770040)" . . . "strain; micro-CT; digital volume correlation"@en . "3"^^ . . "2"^^ .