"Experimental setup for measurement of unsteady flow"@en . . "Pr\u00E1ce se zab\u00FDv\u00E1 popisem sestaven\u00ED nov\u00E9 m\u011B\u0159ic\u00ED trat\u011B v Laborato\u0159i pro hemodynamiku a nestacion\u00E1rn\u00ED proud\u011Bn\u00ED. Kl\u00ED\u010Dov\u00FDm prvkem je z\u00E1stavba \u0159iditeln\u00E9ho \u010Derpadla PhysioPulse 100 vyr\u00E1b\u011Bn\u00FDm firmou Simutec (www.simutec.com). Z\u00E1kladn\u00EDm parametrem \u010Derpadla je \u0159iditeln\u00FD tok v rozsahu od 1 do 100 ml/s. Tomuto rozsahu toku byl p\u0159izp\u016Fsoben i zbytek trat\u011B, kdy za nomin\u00E1ln\u00ED pr\u016Fm\u011Br trubice vyu\u017E\u00EDvan\u00FDch model\u016F byl zvolen pr\u016Fm\u011Br 3/4 palce, nebo d\u00E1le 19 mm. Testovac\u00ED m\u011B\u0159en\u00ED prob\u011Bhlo s upokojiv\u00FDmi v\u00FDsledky i na modelech nomin\u00E1ln\u00EDho pr\u016Fm\u011Bru 26 mm, prob\u011Bhlo m\u011B\u0159en\u00ED tak\u00E9 na modelech nomin\u00E1ln\u00EDho pr\u016Fm\u011Bru 11 mm, kter\u00E9 ji\u017E nedalo uspokojiv\u00E9 v\u00FDsledky z d\u016Fvodu vyu\u017Eit\u00ED doln\u00ED meze rozsahu toku \u010Derpadla, kde se m\u011B\u0159iteln\u011B projevil nespojit\u00FD chod \u010Derpac\u00EDho mechanismu."@cs . "3"^^ . "Sestaven\u00ED a ov\u011B\u0159en\u00ED experiment\u00E1ln\u00ED trat\u011B pro m\u011B\u0159en\u00ED parametr\u016F nestacion\u00E1rn\u00EDho proud\u011Bn\u00ED"@cs . "Experimental fluid dynamics"@en . . . . . "Paper deals with set up an experimental measuring equipement for usteady flow. The key element of new experimental equipement is a contolable pump."@en . "Experimental setup for measurement of unsteady flow"@en . "I" . "Sestaven\u00ED a ov\u011B\u0159en\u00ED experiment\u00E1ln\u00ED trat\u011B pro m\u011B\u0159en\u00ED parametr\u016F nestacion\u00E1rn\u00EDho proud\u011Bn\u00ED" . "21220" . . . . "104809" . "RIV/68407700:21220/13:00214731!RIV14-MSM-21220___" . "Nov\u00E1kov\u00E1, Ludmila" . "3"^^ . . "[2D989AFF0220]" . "Sestaven\u00ED a ov\u011B\u0159en\u00ED experiment\u00E1ln\u00ED trat\u011B pro m\u011B\u0159en\u00ED parametr\u016F nestacion\u00E1rn\u00EDho proud\u011Bn\u00ED" . . "Kol\u00EDnsk\u00FD, Jan" . . . . "8"^^ . "Sestaven\u00ED a ov\u011B\u0159en\u00ED experiment\u00E1ln\u00ED trat\u011B pro m\u011B\u0159en\u00ED parametr\u016F nestacion\u00E1rn\u00EDho proud\u011Bn\u00ED"@cs . "Pr\u00E1ce se zab\u00FDv\u00E1 popisem sestaven\u00ED nov\u00E9 m\u011B\u0159ic\u00ED trat\u011B v Laborato\u0159i pro hemodynamiku a nestacion\u00E1rn\u00ED proud\u011Bn\u00ED. Kl\u00ED\u010Dov\u00FDm prvkem je z\u00E1stavba \u0159iditeln\u00E9ho \u010Derpadla PhysioPulse 100 vyr\u00E1b\u011Bn\u00FDm firmou Simutec (www.simutec.com). Z\u00E1kladn\u00EDm parametrem \u010Derpadla je \u0159iditeln\u00FD tok v rozsahu od 1 do 100 ml/s. Tomuto rozsahu toku byl p\u0159izp\u016Fsoben i zbytek trat\u011B, kdy za nomin\u00E1ln\u00ED pr\u016Fm\u011Br trubice vyu\u017E\u00EDvan\u00FDch model\u016F byl zvolen pr\u016Fm\u011Br 3/4 palce, nebo d\u00E1le 19 mm. Testovac\u00ED m\u011B\u0159en\u00ED prob\u011Bhlo s upokojiv\u00FDmi v\u00FDsledky i na modelech nomin\u00E1ln\u00EDho pr\u016Fm\u011Bru 26 mm, prob\u011Bhlo m\u011B\u0159en\u00ED tak\u00E9 na modelech nomin\u00E1ln\u00EDho pr\u016Fm\u011Bru 11 mm, kter\u00E9 ji\u017E nedalo uspokojiv\u00E9 v\u00FDsledky z d\u016Fvodu vyu\u017Eit\u00ED doln\u00ED meze rozsahu toku \u010Derpadla, kde se m\u011B\u0159iteln\u011B projevil nespojit\u00FD chod \u010Derpac\u00EDho mechanismu." . . . "RIV/68407700:21220/13:00214731" . "Adamec, Josef" .