"[DD5E06C7128C]" . "8" . . "27"^^ . "RIV/68407700:21220/13:00201919!RIV14-MSM-21220___" . "8"^^ . . "1748-0221" . . . "21220" . . "Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors" . . "http://iopscience.iop.org/1748-0221/8/01" . "Doubek, Martin" . . . "Precision sound velocity measurements can simultaneously determine binary gas composition. We have developed an analyzer with custom electronics, currently in use in the ATLAS inner detector, with numerous potential applications. Moderate and high flow versions of the instrument have demonstrated flow resolutions of +/-2% of full scale for flows up to 250 l min-1, and 1.9% of full scale for linear flow velocities up to 15ms-1; the latter flow approaching that expected in the vapour return of the thermosiphon fluorocarbon coolant recirculator being built for the ATLAS silicon tracker."@en . "Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors"@en . "000320665400002" . "V\u00EDtek, Michal" . . "Journal of Instrumentation" . "3"^^ . "10.1088/1748-0221/8/01/C01002" . "Bozza, G." . "Bates, R." . . "RIV/68407700:21220/13:00201919" . "Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors" . "Da Riva, E." . . "Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors"@en . "P(LA08015), P(LA08032)" . . "Detector cooling and thermo-stabilization; Gas systems and purification; Materials for gaseous detectors"@en . "01" . . . . . . "Battistin, M." . "Precision sound velocity measurements can simultaneously determine binary gas composition. We have developed an analyzer with custom electronics, currently in use in the ATLAS inner detector, with numerous potential applications. Moderate and high flow versions of the instrument have demonstrated flow resolutions of +/-2% of full scale for flows up to 250 l min-1, and 1.9% of full scale for linear flow velocities up to 15ms-1; the latter flow approaching that expected in the vapour return of the thermosiphon fluorocarbon coolant recirculator being built for the ATLAS silicon tracker." . . "Vacek, V\u00E1clav" . . "Hallewell, G." . "GB - Spojen\u00E9 kr\u00E1lovstv\u00ED Velk\u00E9 Brit\u00E1nie a Severn\u00EDho Irska" . "69073" .