. . "A Tribological Method for Testing of Materials for Artifical Knee Joints"@en . "[CC94EA018256]" . "Franta, Luk\u00E1\u0161" . "Chlup, Hynek" . "RIV/68407700:21220/06:02123144" . . "21220" . . . "Human Biomechanics 2006" . . "Tribologick\u00E9 metody testov\u00E1n\u00ED materi\u00E1l\u016F um\u011Bl\u00FDch kloubn\u00EDch n\u00E1hrad"@cs . . . . . . "RIV/68407700:21220/06:02123144!RIV08-MSM-21220___" . "Tribologick\u00E9 metody testov\u00E1n\u00ED materi\u00E1l\u016F um\u011Bl\u00FDch kloubn\u00EDch n\u00E1hrad"@cs . "Z(AV0Z20760514), Z(MSM6840770012)" . "A Tribological Method for Testing of Materials for Artifical Knee Joints" . "80-214-3232-2" . "Vysok\u00E9 u\u010Den\u00ED technick\u00E9 v Brn\u011B" . "2006-11-13+01:00"^^ . "Pra\u017E\u00E1k, J." . "biotribology; joint prostheses; total artificial joints; wear"@en . . . . "3"^^ . "A Tribological Method for Testing of Materials for Artifical Knee Joints"@en . . "Hrotovice" . . "In order to achieve a high functional quality of the total artificial joints (TAJ), a special attention must be paid to the selection of suitable materials for the construction (Dumbleton; 1981, O\u00B4Kelly; 1979). Nowadays, it seems that the metal parts of the assembly (femoral part for the knee joint) do not pose any problem, but problems of the %22soft%22 parts (tibial part) persist. A careful tribologic testing of considered materials is necessary, consequently. On the other hand, a relevant tribologic testing in a conventional way is extremely time-consuming (a simulation of a 5 km/day for 10 years activity represents a 150 day test approx.). The application of an accelerated testing method is desirable, therefore. Such a method consisting of an application of a special experimental set-up and of an optical evaluation was developed. It was used for a study concerning the lubrication of artificial joints (Pra\u017E\u00E1k; 2000)."@en . . . "2"^^ . "463897" . "Ne\u010D\u00EDslov\u00E1no" . "4"^^ . . "A Tribological Method for Testing of Materials for Artifical Knee Joints" . "In order to achieve a high functional quality of the total artificial joints (TAJ), a special attention must be paid to the selection of suitable materials for the construction (Dumbleton; 1981, O\u00B4Kelly; 1979). Nowadays, it seems that the metal parts of the assembly (femoral part for the knee joint) do not pose any problem, but problems of the %22soft%22 parts (tibial part) persist. A careful tribologic testing of considered materials is necessary, consequently. On the other hand, a relevant tribologic testing in a conventional way is extremely time-consuming (a simulation of a 5 km/day for 10 years activity represents a 150 day test approx.). The application of an accelerated testing method is desirable, therefore. Such a method consisting of an application of a special experimental set-up and of an optical evaluation was developed. It was used for a study concerning the lubrication of artificial joints (Pra\u017E\u00E1k; 2000)." . "Brno" . "In order to achieve a high functional quality of the total artificial joints (TAJ), a special attention must be paid to the selection of suitable materials for the construction (Dumbleton; 1981, O\u00B4Kelly; 1979). Nowadays, it seems that the metal parts of the assembly (femoral part for the knee joint) do not pose any problem, but problems of the %22soft%22 parts (tibial part) persist. A careful tribologic testing of considered materials is necessary, consequently. On the other hand, a relevant tribologic testing in a conventional way is extremely time-consuming (a simulation of a 5 km/day for 10 years activity represents a 150 day test approx.). The application of an accelerated testing method is desirable, therefore. Such a method consisting of an application of a special experimental set-up and of an optical evaluation was developed. It was used for a study concerning the lubrication of artificial joints (Pra\u017E\u00E1k; 2000)."@cs .