"479967" . "9"^^ . "RIV/68407700:21220/06:02119354!RIV07-MSM-21220___" . "Institute of Chemical Engineering Vienna University of Technology" . "504 ; 512" . . . . . "Chemical Industry and Environment V" . "Z(MSM6840770011)" . "21220" . . . "Intensification of Pulse-Jet Cleaning of Industrial Filters" . . "Intenzifikace pulzn\u00ED regenerace pr\u016Fmyslov\u00FDch filtr\u016F"@cs . "Intensification of Pulse-Jet Cleaning of Industrial Filters" . . "filter volume; filtration; filtration hose; industrial filter; pulse-jet; regeneration"@en . "2"^^ . "V\u00EDde\u0148" . "V\u00EDde\u0148" . "P\u0159\u00EDsp\u011Bvek se zab\u00FDv\u00E1 vlivem velikosti voln\u00E9ho objemu prostoru v\u00FDstupn\u00ED a vstupn\u00ED \u010D\u00E1sti filtru. Experimenty se prov\u00E1d\u011Bly na zku\u0161ebn\u00EDm filtru s jednou filtra\u010Dn\u00ED hadic\u00ED. Pro hodnocen\u00ED testovan\u00FDch alternativ uspo\u0159\u00E1d\u00E1n\u00ED filtru byl pou\u017Eit bodov\u00FD hodnot\u00EDc\u00ED syst\u00E9m. Ten se skl\u00E1d\u00E1 ze 6 hodnot\u00EDc\u00EDch hledisek, kter\u00E1 vych\u00E1zej\u00ED ze zji\u0161t\u011Bn\u00FDch pr\u016Fb\u011Bh\u016F tlak\u016F. Prvn\u00ED experimenty uk\u00E1zaly zna\u010Dn\u00FD vliv velikosti objemu vstupn\u00ED a v\u00FDstupn\u00ED \u010D\u00E1sti filtru na \u00FA\u010Dinnost pulzn\u00ED regenerace. Pro detailn\u00ED v\u00FDzkum prob\u011Bhla rekonstrukce zku\u0161ebn\u00EDho filtru a bylo otestov\u00E1no 16 alternativ uspo\u0159\u00E1d\u00E1n\u00ED filtru. Nejl\u00E9pe ohodnocena byla varianta s nejv\u011Bt\u0161\u00EDm objemem obou \u010D\u00E1st\u00ED filtru. Ka\u017Ed\u00E9 zv\u011Bt\u0161en\u00ED objemu, a\u0165 na vstupu nebo v\u00FDstupu, vede ke zv\u00FD\u0161en\u00ED bodov\u00E9ho ohodnocen\u00ED alternativy, co\u017E znamen\u00E1 vy\u0161\u0161\u00ED \u00FA\u010Dinnost pulzn\u00ED regenerace. Tuto \u00FA\u010Dinnost je nutno ch\u00E1pat jako vyu\u017Eit\u00ED energie tlakov\u00E9ho vzduchu pro odstran\u011Bn\u00ED filtra\u010Dn\u00EDho kol\u00E1\u010De, ovliv\u0148uj\u00EDc\u00ED m\u011Brnou spot\u0159ebu tlakov\u00E9ho vzduchu, provozn\u00ED tlakovou ztr\u00E1tu filtru a tud\u00ED\u017E provozn\u00ED n\u00E1klady."@cs . "Hemerka, Ji\u0159\u00ED" . . "3-900554-57-9" . "Vyb\u00EDral, Pavel" . "2"^^ . "Intensification of Pulse-Jet Cleaning of Industrial Filters"@en . . . . . "The paper deals with the influence of free volume rate of the outlet and inlet part of the filter. An experimental filter unit with a single filter bag was used for measurement. For evaluation of the tested alternatives a point evaluation system was used. It comprises 6 evaluation factors, which follow from the measured pressure time dependence. First experiments showed that volumes of the inlet and outlet filter parts have a significant influence on the pulse-jet cleaning efficiency. For a more detailed research the experimental filter was reconstructed. 16 alternatives of the filter arrangement were tested. The best was the alternative with the largest volumes on both sides of the filter. The size of the outlet as well as the inlet volume has a positive influence on the point evaluation of the alternative. This conclusion has a considerable influence on the pulse-jet cleaning efficiency and thus on the pressurized air consumption, the filter pressure loss and operational costs."@en . . . "RIV/68407700:21220/06:02119354" . . "2006-05-02+02:00"^^ . . . "Intenzifikace pulzn\u00ED regenerace pr\u016Fmyslov\u00FDch filtr\u016F"@cs . "The paper deals with the influence of free volume rate of the outlet and inlet part of the filter. An experimental filter unit with a single filter bag was used for measurement. For evaluation of the tested alternatives a point evaluation system was used. It comprises 6 evaluation factors, which follow from the measured pressure time dependence. First experiments showed that volumes of the inlet and outlet filter parts have a significant influence on the pulse-jet cleaning efficiency. For a more detailed research the experimental filter was reconstructed. 16 alternatives of the filter arrangement were tested. The best was the alternative with the largest volumes on both sides of the filter. The size of the outlet as well as the inlet volume has a positive influence on the point evaluation of the alternative. This conclusion has a considerable influence on the pulse-jet cleaning efficiency and thus on the pressurized air consumption, the filter pressure loss and operational costs." . "Intensification of Pulse-Jet Cleaning of Industrial Filters"@en . "[D1890185F7B2]" . . .