. "1210-9592" . "The System for Measurement of Distribution of Static and Dynamic Pressure for Biomechanic Application"@en . "The article us dedicated to system for measurement of static and dynamic distribution pressures. This transducer was developed to analysis of human walking,pressure distribution on sole,setting position and to indication of big joint condition.Matrix transducer of dynamic pressure was developed to analysis of human walking.System was created by transducerwith 7500 sensors,which are placed equally on area 300x400 mm.The transducer is controled by computer,itspossible analyse of 60 snaps per 200 ms(snap frekvency 300 Hz).Conductive elastomer is used as converter force-electrical signal."@en . . "Syst\u00E9m pro m\u011B\u0159en\u00ED rozlo\u017Een\u00ED statick\u00FDch a dynamick\u00FDch tlak\u016F pro biomechanick\u00E9 aplikace"@cs . "CZ - \u010Cesk\u00E1 republika" . . "Syst\u00E9m pro m\u011B\u0159en\u00ED rozlo\u017Een\u00ED statick\u00FDch a dynamick\u00FDch tlak\u016F pro biomechanick\u00E9 aplikace"@cs . "Syst\u00E9m pro m\u011B\u0159en\u00ED rozlo\u017Een\u00ED statick\u00FDch a dynamick\u00FDch tlak\u016F pro biomechanick\u00E9 aplikace" . "17;19" . "11" . "21220" . . "3"^^ . . . . "Volf, Jarom\u00EDr" . "Automa" . "Measurement,Pressure,Distribution,Sensor,Transducer,Biomechanics"@en . . "Syst\u00E9m pro m\u011B\u0159en\u00ED rozlo\u017Een\u00ED statick\u00FDch a dynamick\u00FDch tlak\u016F pro biomechanick\u00E9 aplikace" . . "The System for Measurement of Distribution of Static and Dynamic Pressure for Biomechanic Application"@en . . . "RIV/68407700:21220/02:02078641" . . . "666262" . . . . . "0"^^ . "1"^^ . "0"^^ . "\u010Cl\u00E1nek je v\u011Bnov\u00E1n syst\u00E9mu pro m\u011B\u0159en\u00ED rozlo\u017Een\u00ED statick\u00FDch a dynamick\u00FDch tlak\u016F,kter\u00FD byl vyvinut k anal\u00FDze ch\u016Fze \u010Dlov\u011Bka,rozlo\u017Een\u00ED tlak\u016F na olosce chodidla,sedu a k indikaci stavu velk\u00FDch kloub\u016F.Syst\u00E9m tvo\u0159\u00ED sn\u00EDma\u010D\u010D,kter\u00FD obsahuje 7500 \u010Didel,um\u00EDst\u011Bn\u00FDch rovnom\u011Brn\u011B na plo\u0161e 300x400mm,je \u0159\u00EDzen po\u010D\u00EDta\u010Dem a umo\u017E\u0148uje analyzovat a\u017E 60 sn\u00EDmk\u016F za 200ms(300 sn\u00EDmk\u016F za sekundu). Jako p\u0159evodn\u00EDk s\u00EDly na elektrick\u00FD sign\u00E1l je pou\u017Eit vodiv\u00FD elastomer.Na jeho v\u00FDvoji se pod\u00EDleli pracovn\u00EDci \u00DAstavu p\u0159\u00EDstrojov\u00E9 a \u0159\u00EDd\u00EDc\u00ED techniky a \u00DAstavu mechaniky Strojn\u00ED fakulty \u010CVUT v Praze,katedry anatomie Fakulty t\u011Blesn\u00E9 v\u00FDchovy a sportu Univerzity Karlovy v Praze a Rehabilita\u010Dn\u00ED kliniky Fakultn\u00ED nemocnice Kr\u00E1lovsk\u00E9 Vinohrady." . "1"^^ . "[F65119E2AEB1]" . "8" . . "P(GA106/00/1464)" . "RIV/68407700:21220/02:02078641!RIV/2003/GA0/212203/N" .