"The continuously rising energy prices and the necessity of environmental protection in the last years have brought about on-going tightening the heat engineering requirements for building structures. In the case of external skins of buildings, these can now hardly fulfill the values recommended by the respective standard without using a thermal insulation system. The envelope masonry of newly built and existing buildings is presently most commonly padded by a contact padding system - ETICS applying expanded polystyrene foam as thermal insulation. The persisting risks of fires of external structures, mainly those applying plastics, however, require special care in designing and assessing these structures in terms of fire safety."@en . . "Rostouc\u00ED ceny energi\u00ED a nutnost ochrany \u017Eivotn\u00EDho prost\u0159ed\u00ED v posledn\u00EDch letech vyvol\u00E1v\u00E1 pr\u016Fb\u011B\u017En\u00E9 zp\u0159\u00EDs\u0148ov\u00E1n\u00ED tepeln\u011B technick\u00FDch po\u017Eadavk\u016F na stavebn\u00ED objekty. Normov\u00E9 po\u017Eadavky kladou vysok\u00E9 n\u00E1roky na tepeln\u011B izola\u010Dn\u00ED schopnost obalov\u00FDch konstrukc\u00ED a v p\u0159\u00EDpad\u011B novostaveb se \u010Dast\u011Bji ne\u017E masivn\u011Bj\u0161\u00ED jednovrstv\u00E9 obvodov\u00E9 zdivo vyu\u017E\u00EDv\u00E1 zdiva men\u0161\u00EDch tlou\u0161\u0165ek s vn\u011Bj\u0161\u00EDm kontaktn\u00EDm zateplovac\u00EDm syst\u00E9mem s tepeln\u00FDm izolantem z miner\u00E1ln\u00ED vlny nebo \u010Dast\u011Bji p\u011Bnov\u00E9ho polystyrenu. Pr\u00E1v\u011B p\u011Bnov\u00FD polystyren je z hlediska mnoha pozitivn\u00EDch vlastnost\u00ED hojn\u011B vyu\u017E\u00EDv\u00E1n pro tato zateplen\u00ED, av\u0161ak z pohledu po\u017E\u00E1rn\u00ED bezpe\u010Dnosti se ji\u017E n\u00E1zory na jeho aplikaci zna\u010Dn\u011B r\u016Fzn\u00ED. Z\u00E1vady kontaktn\u00EDch zateplovac\u00EDch syst\u00E9m\u016F mohou vznikat ve f\u00E1zi chybn\u00E9ho projektu, realizace \u010Di vlastn\u00EDho st\u00E1rnut\u00ED. Z\u00E1m\u011Brem \u010Dl\u00E1nku nen\u00ED jen popsat chov\u00E1n\u00ED samotn\u00E9ho p\u011Bnov\u00E9ho polystyrenu v p\u0159\u00EDpad\u011B po\u017E\u00E1ru, ale zohlednit jeho mo\u017En\u00E9 chov\u00E1n\u00ED v zateplovac\u00EDm syst\u00E9mu a d\u00E1le pojednat o zateplen\u00ED jako syst\u00E9mu z pohledu po\u017E\u00E1rn\u00EDch norem." . . "11"^^ . "1"^^ . "406523" . "[8B2AC142BDC6]" . . "RIV/68407700:21110/08:01154169" . . "Pokorn\u00FD, Marek" . . "Z\u00E1vady vn\u011Bj\u0161\u00EDch kontaktn\u00EDch zateplovac\u00EDch syst\u00E9m\u016F z po\u017E\u00E1rn\u00EDho hlediska" . "Praha" . "Defects of External Thermally Insulating Composite Systems in Terms of Fire Safety"@en . . "WTA CZ" . . "S" . . . "Z\u00E1vady vn\u011Bj\u0161\u00EDch kontaktn\u00EDch zateplovac\u00EDch syst\u00E9m\u016F z po\u017E\u00E1rn\u00EDho hlediska"@cs . . "Z\u00E1vady vn\u011Bj\u0161\u00EDch kontaktn\u00EDch zateplovac\u00EDch syst\u00E9m\u016F z po\u017E\u00E1rn\u00EDho hlediska" . "Z\u00E1vady vn\u011Bj\u0161\u00EDch kontaktn\u00EDch zateplovac\u00EDch syst\u00E9m\u016F z po\u017E\u00E1rn\u00EDho hlediska"@cs . . "Brno" . "978-80-02-01998-5" . . . "21110" . . "2008-03-06+01:00"^^ . . "ETICS; defect; fire safety; expanded polystyrene foam"@en . "Defects of External Thermally Insulating Composite Systems in Terms of Fire Safety"@en . "RIV/68407700:21110/08:01154169!RIV09-MSM-21110___" . "Sanace a rekonstrukce staveb 2008" . "Rostouc\u00ED ceny energi\u00ED a nutnost ochrany \u017Eivotn\u00EDho prost\u0159ed\u00ED v posledn\u00EDch letech vyvol\u00E1v\u00E1 pr\u016Fb\u011B\u017En\u00E9 zp\u0159\u00EDs\u0148ov\u00E1n\u00ED tepeln\u011B technick\u00FDch po\u017Eadavk\u016F na stavebn\u00ED objekty. Normov\u00E9 po\u017Eadavky kladou vysok\u00E9 n\u00E1roky na tepeln\u011B izola\u010Dn\u00ED schopnost obalov\u00FDch konstrukc\u00ED a v p\u0159\u00EDpad\u011B novostaveb se \u010Dast\u011Bji ne\u017E masivn\u011Bj\u0161\u00ED jednovrstv\u00E9 obvodov\u00E9 zdivo vyu\u017E\u00EDv\u00E1 zdiva men\u0161\u00EDch tlou\u0161\u0165ek s vn\u011Bj\u0161\u00EDm kontaktn\u00EDm zateplovac\u00EDm syst\u00E9mem s tepeln\u00FDm izolantem z miner\u00E1ln\u00ED vlny nebo \u010Dast\u011Bji p\u011Bnov\u00E9ho polystyrenu. Pr\u00E1v\u011B p\u011Bnov\u00FD polystyren je z hlediska mnoha pozitivn\u00EDch vlastnost\u00ED hojn\u011B vyu\u017E\u00EDv\u00E1n pro tato zateplen\u00ED, av\u0161ak z pohledu po\u017E\u00E1rn\u00ED bezpe\u010Dnosti se ji\u017E n\u00E1zory na jeho aplikaci zna\u010Dn\u011B r\u016Fzn\u00ED. Z\u00E1vady kontaktn\u00EDch zateplovac\u00EDch syst\u00E9m\u016F mohou vznikat ve f\u00E1zi chybn\u00E9ho projektu, realizace \u010Di vlastn\u00EDho st\u00E1rnut\u00ED. Z\u00E1m\u011Brem \u010Dl\u00E1nku nen\u00ED jen popsat chov\u00E1n\u00ED samotn\u00E9ho p\u011Bnov\u00E9ho polystyrenu v p\u0159\u00EDpad\u011B po\u017E\u00E1ru, ale zohlednit jeho mo\u017En\u00E9 chov\u00E1n\u00ED v zateplovac\u00EDm syst\u00E9mu a d\u00E1le pojednat o zateplen\u00ED jako syst\u00E9mu z pohledu po\u017E\u00E1rn\u00EDch norem."@cs . "1"^^ . .