"4"^^ . "RIV/68378297:_____/14:00433996!RIV15-MK0-68378297" . . . . "Bl\u00E1ha, Ji\u0159\u00ED" . "Kloiber, Michal" . "Buzek, Jaroslav" . . . . "Research Report on Condition Assessment of the Holy Ghost Tower's Roof Frame in Tel\u010D"@en . "P\u0159edm\u011Btem v\u00FDzkumn\u00E9 zpr\u00E1vy bylo posouzen\u00ED stavu a identifikace rozsahu d\u0159evokazn\u00E9ho po\u0161kozen\u00ED krovu v\u011B\u017Ee sv. Ducha v Tel\u010Di se zam\u011B\u0159en\u00EDm na lokalizaci kritick\u00FDch m\u00EDst, klasifikaci stupn\u011B po\u0161kozen\u00ED, ur\u010Den\u00ED rozsahu skryt\u00E9ho napaden\u00ED pomoc\u00ED nedestruktivn\u00EDch p\u0159\u00EDstroj\u016F, specifikaci napaden\u00ED d\u0159eva houbami (mykologie) a hmyzem (entomologie), v\u010Detn\u011B zakreslen\u00ED zji\u0161t\u011Bn\u00FDch v\u00FDsledk\u016F do kresebn\u00E9 dokumentace st\u00E1vaj\u00EDc\u00EDho stavu krovu. Na z\u00E1klad\u011B v\u00FDsledk\u016F byly navr\u017Eeny konkr\u00E9tn\u00ED postupy pro sana\u010Dn\u00ED opat\u0159en\u00ED a do v\u00FDkresov\u00E9 dokumentace zakresleny prvky navr\u017Een\u00E9 ke konstruk\u010Dn\u00ED sanaci. Zpr\u00E1va je zalo\u017Eena p\u0159edev\u0161\u00EDm na p\u0159\u00EDm\u00E9m a zprost\u0159edkovan\u00E9m (endoskopick\u00E9m) vizu\u00E1ln\u00EDm pozorov\u00E1n\u00ED dopln\u011Bn\u00E9m o m\u011B\u0159en\u00ED pomoc\u00ED p\u0159\u00EDstroje pro odporov\u00E9 mikrovrt\u00E1n\u00ED." . "V\u00FDzkumn\u00E1 zpr\u00E1va z hodnocen\u00ED stavu krovu v\u011B\u017Ee sv. Ducha v Tel\u010Di" . "Frankl, Ji\u0159\u00ED" . "P\u0159edm\u011Btem v\u00FDzkumn\u00E9 zpr\u00E1vy bylo posouzen\u00ED stavu a identifikace rozsahu d\u0159evokazn\u00E9ho po\u0161kozen\u00ED krovu v\u011B\u017Ee sv. Ducha v Tel\u010Di se zam\u011B\u0159en\u00EDm na lokalizaci kritick\u00FDch m\u00EDst, klasifikaci stupn\u011B po\u0161kozen\u00ED, ur\u010Den\u00ED rozsahu skryt\u00E9ho napaden\u00ED pomoc\u00ED nedestruktivn\u00EDch p\u0159\u00EDstroj\u016F, specifikaci napaden\u00ED d\u0159eva houbami (mykologie) a hmyzem (entomologie), v\u010Detn\u011B zakreslen\u00ED zji\u0161t\u011Bn\u00FDch v\u00FDsledk\u016F do kresebn\u00E9 dokumentace st\u00E1vaj\u00EDc\u00EDho stavu krovu. Na z\u00E1klad\u011B v\u00FDsledk\u016F byly navr\u017Eeny konkr\u00E9tn\u00ED postupy pro sana\u010Dn\u00ED opat\u0159en\u00ED a do v\u00FDkresov\u00E9 dokumentace zakresleny prvky navr\u017Een\u00E9 ke konstruk\u010Dn\u00ED sanaci. Zpr\u00E1va je zalo\u017Eena p\u0159edev\u0161\u00EDm na p\u0159\u00EDm\u00E9m a zprost\u0159edkovan\u00E9m (endoskopick\u00E9m) vizu\u00E1ln\u00EDm pozorov\u00E1n\u00ED dopln\u011Bn\u00E9m o m\u011B\u0159en\u00ED pomoc\u00ED p\u0159\u00EDstroje pro odporov\u00E9 mikrovrt\u00E1n\u00ED."@cs . "RIV/68378297:_____/14:00433996" . . . . . "P(DF11P01OVV001), P(LO1219)" . "V\u00FDzkumn\u00E1 zpr\u00E1va z hodnocen\u00ED stavu krovu v\u011B\u017Ee sv. Ducha v Tel\u010Di" . . "The subject of the research report was to assess the condition of and identify the range of wood-destroying damage to the roof frame of the Holy Ghost tower in Tel\u010D focused on locating critical points, classifying the degree of damage, determining the extent of concealed attack by the means of non-destructive devices, specifying whether wood is subject to a fungal attack (mycology) or insect attack (entomology), including the drawing of the results obtained in the drawing documentation of the existing condition of the roof frame. Based on the results, specific procedures for rehabilitation measures were designed and elements designed for structural rehabilitation were included in the drawing documentation. The report is based primarily on direct and mediated (endoscopic) visual observations supplemented by measurements using a resistance microdrilling device."@en . . . . . . . "[7473E22B6933]" . "tower; roof; diagnostics of wood"@en . "V\u00FDzkumn\u00E1 zpr\u00E1va z hodnocen\u00ED stavu krovu v\u011B\u017Ee sv. Ducha v Tel\u010Di"@cs . . "4"^^ . "55626" . "V\u00FDzkumn\u00E1 zpr\u00E1va z hodnocen\u00ED stavu krovu v\u011B\u017Ee sv. Ducha v Tel\u010Di"@cs . "Research Report on Condition Assessment of the Holy Ghost Tower's Roof Frame in Tel\u010D"@en . .