. . "Aparatura pro kalibraci r\u016Fzn\u00FDch typ\u016F n\u00EDzkoteplotn\u00EDch sn\u00EDma\u010D\u016F pro m\u011B\u0159en\u00ED teploty"@cs . . . . "Device for calibration of different types of low temperature sensors for temperature measurement"@en . . . . "Funk\u010Dn\u00ED vzorek vyu\u017E\u00EDvan\u00FD p\u0159\u00EDjemcem grantu s mo\u017Enost\u00ED dal\u0161\u00EDho \u0161\u00ED\u0159en\u00ED." . "Funk\u010Dn\u00ED vzorek realizovan\u00FD v r\u00E1mci \u0159e\u0161en\u00ED grantu umo\u017E\u0148uje kalibraci n\u00EDzkoteplotn\u00EDch sn\u00EDma\u010D\u016F r\u016Fzn\u00FDch typ\u016F v rozashu teplot 4,2 K a\u017E 300 K." . . "Za\u0159\u00EDzen\u00ED CalibSen bylo navr\u017Eeno ke kalibrac\u00EDm r\u016Fzn\u00FDch typ\u016F n\u00EDzkoteplotn\u00EDch sn\u00EDma\u010D\u016F pro m\u011B\u0159en\u00ED teploty (Cernox, k\u0159em\u00EDkov\u00E9 diody, germaniov\u00E9 sn\u00EDma\u010De). CalibSen umo\u017E\u0148uje kalibrovat sn\u00EDma\u010De v rozsahu teplot od 4,2 K do 300 K. Sn\u00EDma\u010De jsou pro dan\u00FD kalibra\u010Dn\u00ED bod teplotn\u011B stabilizov\u00E1ny s p\u0159esnost\u00ED 0,1 mK. Nejistota kalibrace z\u00E1vis\u00ED na p\u0159esnosti m\u011B\u0159en\u00ED pou\u017Eit\u00E9ho referen\u010Dn\u00EDho sn\u00EDma\u010De. Lze sou\u010Dasn\u011B porovn\u00E1vat n\u011Bkolik kus\u016F, nap\u0159. u germaniov\u00FDch sn\u00EDma\u010D\u016F typu GR 200A 1500 1.4B jsou to 4 kusy. Sn\u00EDma\u010De se instaluj\u00ED do m\u011Bd\u011Bn\u00E9ho bloku uvnit\u0159 izoterm\u00E1ln\u00ED kalibra\u010Dn\u00ED komory, ke kter\u00E9 je blok tepeln\u011B ukotven. M\u011Bd\u011Bn\u00FD blok je vybaven elektrick\u00FDm odporov\u00FDm topen\u00EDm. Teplota je nastavov\u00E1na a stabilizov\u00E1na p\u0159esn\u00FDm teplotn\u00EDm kontrol\u00E9rem."@cs . "\u00DAstav p\u0159\u00EDstrojov\u00E9 techniky AV \u010CR, v. v. i." . "[AA8AC130A8D9]" . . . . "Aparatura pro kalibraci r\u016Fzn\u00FDch typ\u016F n\u00EDzkoteplotn\u00EDch sn\u00EDma\u010D\u016F pro m\u011B\u0159en\u00ED teploty" . . . "2"^^ . "RIV/68081731:_____/10:00356101!RIV11-AV0-68081731" . "247219" . "Aparatura pro kalibraci r\u016Fzn\u00FDch typ\u016F n\u00EDzkoteplotn\u00EDch sn\u00EDma\u010D\u016F pro m\u011B\u0159en\u00ED teploty" . "2"^^ . . "RIV/68081731:_____/10:00356101" . "calibration device; comparative calibration; temperature sensors"@en . "Device for calibration of different types of low temperature sensors for temperature measurement"@en . "201014" . "P(KJB200650902), Z(AV0Z20650511)" . . "Calibration device was designed for calibration of different types of low temperature sensors (Cernox, silicon diodes, germanium sensors). Device allows calibration of temperature sensors in the range from 4.2 K to 300 K (according to the type of sensor). Temperature stability is 0.1 mK for one calibration point. Uncertainty of calibration depends on the accuracy of temperature sensors which is used as a temperature standard. It is possible to compare simultaneously some pieces of sensors, e.g. in the case of germanium sensors GR 200A 1500 1.4B four ones. Sensors are mounted into a copper block. This block is placed in a copper case which is equipped with an electrical heater. Calibration is performed in four-lead connection of the sensors to eliminate the lead resistance. The temperature of the case is set and stabilized by the temperature controller."@en . "Za\u0159\u00EDzen\u00ED CalibSen bylo navr\u017Eeno ke kalibrac\u00EDm r\u016Fzn\u00FDch typ\u016F n\u00EDzkoteplotn\u00EDch sn\u00EDma\u010D\u016F pro m\u011B\u0159en\u00ED teploty (Cernox, k\u0159em\u00EDkov\u00E9 diody, germaniov\u00E9 sn\u00EDma\u010De). CalibSen umo\u017E\u0148uje kalibrovat sn\u00EDma\u010De v rozsahu teplot od 4,2 K do 300 K. Sn\u00EDma\u010De jsou pro dan\u00FD kalibra\u010Dn\u00ED bod teplotn\u011B stabilizov\u00E1ny s p\u0159esnost\u00ED 0,1 mK. Nejistota kalibrace z\u00E1vis\u00ED na p\u0159esnosti m\u011B\u0159en\u00ED pou\u017Eit\u00E9ho referen\u010Dn\u00EDho sn\u00EDma\u010De. Lze sou\u010Dasn\u011B porovn\u00E1vat n\u011Bkolik kus\u016F, nap\u0159. u germaniov\u00FDch sn\u00EDma\u010D\u016F typu GR 200A 1500 1.4B jsou to 4 kusy. Sn\u00EDma\u010De se instaluj\u00ED do m\u011Bd\u011Bn\u00E9ho bloku uvnit\u0159 izoterm\u00E1ln\u00ED kalibra\u010Dn\u00ED komory, ke kter\u00E9 je blok tepeln\u011B ukotven. M\u011Bd\u011Bn\u00FD blok je vybaven elektrick\u00FDm odporov\u00FDm topen\u00EDm. Teplota je nastavov\u00E1na a stabilizov\u00E1na p\u0159esn\u00FDm teplotn\u00EDm kontrol\u00E9rem." . . . "Urban, Pavel" . "Aparatura pro kalibraci r\u016Fzn\u00FDch typ\u016F n\u00EDzkoteplotn\u00EDch sn\u00EDma\u010D\u016F pro m\u011B\u0159en\u00ED teploty"@cs . . . . "Hanzelka, Pavel" . .