. . "Dole\u017Eel, Ivo" . . . "Fault operation regimes of a DC actuator are characterized by overheating and consequent damage of its structural parts, mostly insulation of the field coil. Numerical analysis of such regimes is formulated as a quasi-coupled electromagnetic-temperature problem. Theoretical considerations are illustrated on an actuator with exremely high pull-in force. The results obtained are presented and discussed."@en . "6"^^ . "The University of Newcastle" . "RIV/67985866:_____/04:00020855" . . "Computer Modeling of Selected Fault Regimes of DC Actuators" . "P(LN00B084), Z(AV0Z2057903)" . . "558502" . "Sydney" . . . "Sydney" . "Preprints of the 3rd IFAC Symposium on Mechatronic Systems" . . . . . . "Ulrych, B." . . "RIV/67985866:_____/04:00020855!RIV06-AV0-67985866" . . "Poruchov\u00E9 stavy stejnosm\u011Brn\u00FDch aktu\u00E1tor\u016F jsou \u010Dasto charakterizov\u00E1ny p\u0159eh\u0159\u00E1t\u00EDm a n\u00E1sledn\u00FDm po\u0161kozen\u00EDm exponovan\u00FDch konstruk\u010Dn\u00EDch \u010D\u00E1st\u00ED, zejm\u00E9na izolace budic\u00ED c\u00EDvky. Numerick\u00E1 anal\u00FDza takov\u00FDch stav\u016F je formulov\u00E1na jako quasi-sdru\u017Een\u00FD elektromagneticko-teplotn\u00ED probl\u00E9m. Teoretick\u00E9 \u00FAvahy jsou ilustrov\u00E1ny na v\u00FDpo\u010Dtu aktu\u00E1toru s extr\u00E9mn\u00ED p\u0159\u00EDta\u017Enou silou. je provedena diskuse obdr\u017Een\u00FDch v\u00FDsledk\u016F."@cs . "Computer Modeling of Selected Fault Regimes of DC Actuators"@en . . "Computer Modeling of Selected Fault Regimes of DC Actuators" . "529;534" . "[F439F30226C5]" . "actuators; electromagnetic fields; temperature calculations"@en . "Mach, M." . . "1"^^ . "Po\u010D\u00EDta\u010Dov\u00E9 modelov\u00E1n\u00ED vybran\u00FDch poruchov\u00FDch stav\u016F stejnosm\u011Brn\u00FDch aktu\u00E1tor\u016F"@cs . "Computer Modeling of Selected Fault Regimes of DC Actuators"@en . "2004-09-06+02:00"^^ . "Po\u010D\u00EDta\u010Dov\u00E9 modelov\u00E1n\u00ED vybran\u00FDch poruchov\u00FDch stav\u016F stejnosm\u011Brn\u00FDch aktu\u00E1tor\u016F"@cs . "Fault operation regimes of a DC actuator are characterized by overheating and consequent damage of its structural parts, mostly insulation of the field coil. Numerical analysis of such regimes is formulated as a quasi-coupled electromagnetic-temperature problem. Theoretical considerations are illustrated on an actuator with exremely high pull-in force. The results obtained are presented and discussed." . "Dvo\u0159\u00E1k, P." . . "4"^^ .