"Ackerman, Luk\u00E1\u0161" . "4" . "I, P(KJB300130612), Z(AV0Z30130516), Z(MSM0021620855)" . "1639-4488" . . "Determination of Total Sulfur in Fifteen Geological Materials Using Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) and Combustion/Infrared Spectrometry" . "36" . . . . "Determination of Total Sulfur in Fifteen Geological Materials Using Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) and Combustion/Infrared Spectrometry"@en . "Rohovec, Jan" . "FR - Francouzsk\u00E1 republika" . . . "RIV/67985831:_____/12:00388152!RIV13-AV0-67985831" . "Determination of Total Sulfur in Fifteen Geological Materials Using Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) and Combustion/Infrared Spectrometry" . . . . "000314395900004" . . "10.1111/j.1751-908X.2012.00144.x" . "Geostandards and Geoanalytical Research" . "130661" . "RIV/67985831:_____/12:00388152" . . . "2"^^ . "3"^^ . . . "8"^^ . "sulfur; ICP-OES; combustion; infrared detection; reference materials"@en . . "Determination of Total Sulfur in Fifteen Geological Materials Using Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) and Combustion/Infrared Spectrometry"@en . . . "\u0160ebek, O." . "A method for the determination of total sulfur in geological materials by inductively coupled plasma-optical emission spectrometry (ICP-OES) is described. We show that good results were obtained using this method even for sample types with very low (< 20 \u03BCg g1) sulfur concentration (e.g., peridotite). Sulfur was determined in fifteen geological reference materials with different sulfur contents. For reference materials with certified sulfur contents, the ICP-OES method gave results in excellent agreement with certified values, and uncertainties better than 4% RSD. ICP-OES results for sulfur in other reference materials yielded RSDs better than 10%, where S concentrations were > 100 \u03BCg g1 (except for diabase W-2a, 16% RSD). Reference materials with lower sulfur contents (< 40 \u03BCg g1) showed much higher RSDs (17\u201318%). Except for RMs with certified values for sulfur, most data obtained by the combustion infrared detection method generally showed higher concentrations than those measured by ICP-OES and a better RSD ( 8% for all materials except DTS-2b)." . . . . . . . "[B35129636F3D]" . "A method for the determination of total sulfur in geological materials by inductively coupled plasma-optical emission spectrometry (ICP-OES) is described. We show that good results were obtained using this method even for sample types with very low (< 20 \u03BCg g1) sulfur concentration (e.g., peridotite). Sulfur was determined in fifteen geological reference materials with different sulfur contents. For reference materials with certified sulfur contents, the ICP-OES method gave results in excellent agreement with certified values, and uncertainties better than 4% RSD. ICP-OES results for sulfur in other reference materials yielded RSDs better than 10%, where S concentrations were > 100 \u03BCg g1 (except for diabase W-2a, 16% RSD). Reference materials with lower sulfur contents (< 40 \u03BCg g1) showed much higher RSDs (17\u201318%). Except for RMs with certified values for sulfur, most data obtained by the combustion infrared detection method generally showed higher concentrations than those measured by ICP-OES and a better RSD ( 8% for all materials except DTS-2b)."@en .