. . "P(GA102/08/0691), P(IAA100110502), P(IAA500200510), P(LC06063), Z(AV0Z50110509)" . . . . . "Error Assesment of Volume Reconstruction of Biological Specimen from Confocal Microscopy Images" . "Error Assesment of Volume Reconstruction of Biological Specimen from Confocal Microscopy Images"@en . "5"^^ . "We performed both volume reconstructions using images captured by the USB microscope and images captured by the confocal microscope. We manually marked important corresponding structures in both reconstructed data sets, and computed distances between corresponding structures, assuming that structures in the reconstruction from USB microscope data are without deformations. According to our expectations, the main errors of high-resolution volume reconstruction (from confocal data) are in the direction of physical cutting (vary in units of millimeters) and in the direction perpendicular to cutting due to off-cut (vary in tenths of millimeters)"@en . . "Error Assesment of Volume Reconstruction of Biological Specimen from Confocal Microscopy Images"@en . "H\u00E1na, K." . "2"^^ . . "error assessment; volume reconstruction"@en . . "CTU REPORTS : Proceedings of Workshop 2008" . "Ohodnocen\u00ED chyby objemov\u00E9 rekonstrukce biologick\u00FDch vzork\u016F z konfok\u00E1ln\u00EDch obraz\u016F"@cs . "Jan\u00E1\u010Dek, Ji\u0159\u00ED" . "Objemovou rekonstrukci vyu\u017E\u00EDv\u00E1me pro vizualizaci biologick\u00FDch prepar\u00E1t\u016F, kter\u00E9 jsou v\u011Bt\u0161\u00ED, ne\u017E je velikost zorn\u00E9ho pole a/nebo siln\u011Bj\u0161\u00ED v tlou\u0161\u0165ce ne\u017E je hloubka pr\u016Fniku laserov\u00E9ho paprsku konfok\u00E1ln\u00EDho mikroskopu. Tlust\u00E9 prepar\u00E1ty je nutno nakr\u00E1jet na fyzick\u00E9 \u0159ezy mikrotomem, av\u0161ak kr\u00E1jen\u00ED zp\u016Fsobuje deformaci a ztr\u00E1tu \u010D\u00E1sti informace pro\u0159ezem, kter\u00E9 vedou k chyb\u00E1m n\u00E1sledn\u00E9 objemov\u00E9 rekonstrukce. Pro z\u00EDsk\u00E1n\u00ED informace o deformaci jsme USB mikroskopem Dino-Lite zaznamenali \u0159ezn\u00E9 plochy prepar\u00E1tu zalit\u00E9ho v parafinu p\u0159ed jeho nakr\u00E1jen\u00EDm, tj. bez deformac\u00ED. Po nasn\u00EDm\u00E1n\u00ED fyzick\u00FDch \u0159ez\u016F vyhodnocujeme chybu deformace pomoc\u00ED Prokrustovy vzd\u00E1lenosti, kter\u00E1 kvantifikuje st\u0159edn\u00ED kvadratickou vzd\u00E1lenost tvar\u016F vyj\u00E1d\u0159en\u00FDch pomoc\u00ED bod\u016F"@cs . "Prague" . "3"^^ . "Praha" . "Smr\u010Dka, P." . "Kub\u00EDnov\u00E1, Lucie" . "RIV/67985823:_____/08:00313831" . . . "\u010Capek, Martin" . "Error Assesment of Volume Reconstruction of Biological Specimen from Confocal Microscopy Images" . . . . "2008-02-18+01:00"^^ . . . "978-80-01-04016-4" . . "366466" . . "RIV/67985823:_____/08:00313831!RIV09-AV0-67985823" . "\u010Cesk\u00E1 technika - nakladatelstv\u00ED \u010CVUT" . "Ohodnocen\u00ED chyby objemov\u00E9 rekonstrukce biologick\u00FDch vzork\u016F z konfok\u00E1ln\u00EDch obraz\u016F"@cs . . . "[2C75D976C2DA]" . . . "We performed both volume reconstructions using images captured by the USB microscope and images captured by the confocal microscope. We manually marked important corresponding structures in both reconstructed data sets, and computed distances between corresponding structures, assuming that structures in the reconstruction from USB microscope data are without deformations. According to our expectations, the main errors of high-resolution volume reconstruction (from confocal data) are in the direction of physical cutting (vary in units of millimeters) and in the direction perpendicular to cutting due to off-cut (vary in tenths of millimeters)" .