. . . . . "Spectral analysis of heart rate variability in patients with spinal cord injury"@en . . . . "Opavsk\u00FD, Jaroslav" . "[78A767596E3B]" . "Spectral analysis of heart rate variability in patients with spinal cord injury"@en . . . "Uhl\u00ED\u0159, Petr" . "Zaatar, Amr Mohamed Zaki" . "2" . "CZ - \u010Cesk\u00E1 republika" . "15510" . . . . "Z(MSM6198959221)" . "Ve studii bylo vy\u0161et\u0159eno 10 paraplegik\u016F pr\u016Fm\u011Brn\u00E9ho v\u011Bku 53,1 (+-15,8) let, 7 mu\u017E\u016F a 3 \u017Eeny. Z toho bylo p\u011Bt pacient\u016F s \u00FApln\u00FDm p\u0159eru\u0161en\u00EDm m\u00EDchy a p\u011Bt dal\u0161\u00EDch s poran\u011Bn\u00EDm ne\u00FApln\u00FDm. Autonomn\u00ED reaktivita byla vy\u0161et\u0159ov\u00E1na metodou spektr\u00E1ln\u00ED anal\u00FDzy variability srde\u010Dn\u00ED frekvence (kr\u00E1tkodob\u00E9 z\u00E1znamy) ve zkou\u0161ce se zm\u011Bnami ortostatick\u00E9 z\u00E1t\u011B\u017Ee, kdy byla zvolena zkou\u0161ka leh-sed-leh, kter\u00E1 je modifikac\u00ED zkou\u0161ky leh-stoj-leh. Byl vyu\u017Eit diagnostick\u00FD syst\u00E9m VarCor PF7. Zji\u0161t\u011Bn\u00E1 sn\u00ED\u017Een\u00E1 odpov\u011B\u010F n\u00EDzkofrekven\u010Dn\u00ED slo\u017Eky (LF) spektr\u00E1ln\u00ED anal\u00FDzy variability srde\u010Dn\u00ED frekvence v pozici sedu je z\u0159ejm\u011B korel\u00E1tem sn\u00ED\u017Een\u00E9 aktivity sympatiku a mo\u017En\u00FDch ortostatick\u00FDch poruch t\u011Bchto pacient\u016F p\u0159i zm\u011Bn\u00E1ch polohy t\u011Bla, jak v r\u00E1mci rehabilitace, tak i p\u0159i b\u011B\u017En\u00FDch denn\u00EDch situac\u00EDch." . . . "autonomic nervous system; heart rate variability; spectral analysis; spinal cord injury"@en . "Ten paraplegics (with a mean age of 53.1 +- 15.8 years, seven males and three females) participated in this study. There were five patients with incomplete and five patients with complete spinal cord injury.Autonomic reactivity was evaluated by means of the spectral analysis of heart rate variability (SAHRV) method (short-term registration) using the supine-sitting-supine test. Diagnostic system VarCor PF7 was used. The reduction of the low-frequency component (LF) of the spectral analysis of heart rate variability was registered , it reflects a lowered sympathetic activity in these patients in a sitting position. It reflects ortostatic disturbances in situations with body position changes associated with a modified orthostatic load."@en . "8"^^ . "Acta Universitatis Palackianae Olomucensis. Gymnica" . "1212-1185" . . "4"^^ . "Spektr\u00E1ln\u00ED anal\u00FDza variability srde\u010Dn\u00ED frekvence u pacient\u016F s poran\u011Bn\u00EDm m\u00EDchy"@cs . "RIV/61989592:15510/10:10213575" . "Betlachov\u00E1, Milada" . "40" . . "Spektr\u00E1ln\u00ED anal\u00FDza variability srde\u010Dn\u00ED frekvence u pacient\u016F s poran\u011Bn\u00EDm m\u00EDchy"@cs . "289189" . "Spektr\u00E1ln\u00ED anal\u00FDza variability srde\u010Dn\u00ED frekvence u pacient\u016F s poran\u011Bn\u00EDm m\u00EDchy" . "Ve studii bylo vy\u0161et\u0159eno 10 paraplegik\u016F pr\u016Fm\u011Brn\u00E9ho v\u011Bku 53,1 (+-15,8) let, 7 mu\u017E\u016F a 3 \u017Eeny. Z toho bylo p\u011Bt pacient\u016F s \u00FApln\u00FDm p\u0159eru\u0161en\u00EDm m\u00EDchy a p\u011Bt dal\u0161\u00EDch s poran\u011Bn\u00EDm ne\u00FApln\u00FDm. Autonomn\u00ED reaktivita byla vy\u0161et\u0159ov\u00E1na metodou spektr\u00E1ln\u00ED anal\u00FDzy variability srde\u010Dn\u00ED frekvence (kr\u00E1tkodob\u00E9 z\u00E1znamy) ve zkou\u0161ce se zm\u011Bnami ortostatick\u00E9 z\u00E1t\u011B\u017Ee, kdy byla zvolena zkou\u0161ka leh-sed-leh, kter\u00E1 je modifikac\u00ED zkou\u0161ky leh-stoj-leh. Byl vyu\u017Eit diagnostick\u00FD syst\u00E9m VarCor PF7. Zji\u0161t\u011Bn\u00E1 sn\u00ED\u017Een\u00E1 odpov\u011B\u010F n\u00EDzkofrekven\u010Dn\u00ED slo\u017Eky (LF) spektr\u00E1ln\u00ED anal\u00FDzy variability srde\u010Dn\u00ED frekvence v pozici sedu je z\u0159ejm\u011B korel\u00E1tem sn\u00ED\u017Een\u00E9 aktivity sympatiku a mo\u017En\u00FDch ortostatick\u00FDch poruch t\u011Bchto pacient\u016F p\u0159i zm\u011Bn\u00E1ch polohy t\u011Bla, jak v r\u00E1mci rehabilitace, tak i p\u0159i b\u011B\u017En\u00FDch denn\u00EDch situac\u00EDch."@cs . . . "RIV/61989592:15510/10:10213575!RIV11-MSM-15510___" . "Spektr\u00E1ln\u00ED anal\u00FDza variability srde\u010Dn\u00ED frekvence u pacient\u016F s poran\u011Bn\u00EDm m\u00EDchy" . "4"^^ .