. "RIV/61989592:15110/14:33149537" . . "1" . "Klinick\u00E1 farmakologie a farmacie" . . . . . "Effect of the infusion system on the quality of parenteral treatment"@en . . "53693" . . "RIV/61989592:15110/14:33149537!RIV15-MSM-15110___" . "15110" . "28" . "Pro infuzn\u00ED roztoky jsou v sou\u010Dasnosti pou\u017E\u00EDv\u00E1ny p\u0159edev\u0161\u00EDm flexibiln\u00ED PVC obaly, non-PVC obaly a semirigidn\u00ED plastov\u00E9 obaly. Velkou v\u00FDhodou flexibiln\u00EDch obal\u016F je skute\u010Dnost, \u017Ee ke sv\u00E9mu optim\u00E1ln\u00EDmu vypr\u00E1zdn\u011Bn\u00ED nepot\u0159ebuj\u00ED zavzdu\u0161n\u011Bn\u00ED a mohou b\u00FDt pou\u017Eity v uzav\u0159en\u00FDch infuzn\u00EDch syst\u00E9mech. To minimalizuje rizika kontaminace patogeny ze zevn\u00EDho prost\u0159ed\u00ED a sni\u017Euje riziko z\u00E1va\u017En\u00FDch nozokomi\u00E1ln\u00EDch infekc\u00ED. Nav\u00EDc p\u0159i jejich pou\u017Eit\u00ED z\u016Fst\u00E1v\u00E1 v obalu nejmen\u0161\u00ED dosa\u017Eiteln\u00FD rezidu\u00E1ln\u00ED objem, co\u017E znamen\u00E1, \u017Ee d\u00E1vkov\u00E1n\u00ED rozpu\u0161t\u011Bn\u00FDch l\u00E9\u010Div je velmi p\u0159esn\u00E9."@cs . . "CZ - \u010Cesk\u00E1 republika" . "Vliv infuzn\u00EDho syst\u00E9mu na kvalitu parenter\u00E1ln\u00ED l\u00E9\u010Dby"@cs . "3"^^ . "[57EB3689B757]" . "1212-7973" . . "Poruba, Martin" . "Vliv infuzn\u00EDho syst\u00E9mu na kvalitu parenter\u00E1ln\u00ED l\u00E9\u010Dby"@cs . . "Pro infuzn\u00ED roztoky jsou v sou\u010Dasnosti pou\u017E\u00EDv\u00E1ny p\u0159edev\u0161\u00EDm flexibiln\u00ED PVC obaly, non-PVC obaly a semirigidn\u00ED plastov\u00E9 obaly. Velkou v\u00FDhodou flexibiln\u00EDch obal\u016F je skute\u010Dnost, \u017Ee ke sv\u00E9mu optim\u00E1ln\u00EDmu vypr\u00E1zdn\u011Bn\u00ED nepot\u0159ebuj\u00ED zavzdu\u0161n\u011Bn\u00ED a mohou b\u00FDt pou\u017Eity v uzav\u0159en\u00FDch infuzn\u00EDch syst\u00E9mech. To minimalizuje rizika kontaminace patogeny ze zevn\u00EDho prost\u0159ed\u00ED a sni\u017Euje riziko z\u00E1va\u017En\u00FDch nozokomi\u00E1ln\u00EDch infekc\u00ED. Nav\u00EDc p\u0159i jejich pou\u017Eit\u00ED z\u016Fst\u00E1v\u00E1 v obalu nejmen\u0161\u00ED dosa\u017Eiteln\u00FD rezidu\u00E1ln\u00ED objem, co\u017E znamen\u00E1, \u017Ee d\u00E1vkov\u00E1n\u00ED rozpu\u0161t\u011Bn\u00FDch l\u00E9\u010Div je velmi p\u0159esn\u00E9." . "Vliv infuzn\u00EDho syst\u00E9mu na kvalitu parenter\u00E1ln\u00ED l\u00E9\u010Dby" . "I" . "5"^^ . "3"^^ . "Vliv infuzn\u00EDho syst\u00E9mu na kvalitu parenter\u00E1ln\u00ED l\u00E9\u010Dby" . "\u0160trbov\u00E1, Pavl\u00EDna" . . "blood stream infection; closed system; infusion containers; parenteral treatment"@en . "Effect of the infusion system on the quality of parenteral treatment"@en . . "Urb\u00E1nek, Karel" . "Currently used containers for intravenous infusion solutions are primarily PVC or non-PVC collapsible and semi-rigid plastic containers. Main advantage of flexible containers is the fact that they do not need venting for optimal emptying, thus can be used in closed infusion systems. This minimizes the risk of contamination by the pathogens from the environment, reducing the risk of serious nosocomial infections. Furthermore, after the use only a small residual volume remains in the container, which means that the dosage of the dissolved medicaments is very accurate."@en . . . . .