. "4"^^ . "98023" . "2013-07-01+02:00"^^ . "http://www.atlantis-press.com/php/pub.php?publication=cse-13&frame=http%3A//www.atlantis-press.com/php/paper-details.php%3Fid%3D6893" . . . "RIV/61989100:27240/13:86087277!RIV14-MSM-27240___" . "Power Quality Improvement by Shunt Active Performance Filters Emulated by Artificial Intelligence Techniques"@en . "Paris" . . "Martinek, Radek" . . . . . "Los Angeles" . "\u017D\u00EDdek, Jan" . "This article is focused on progressive strategies of shunt active performance filters with intension to compensate higher harmonic currents of non-linear load. The authors of this article deal with usage of a combination of fuzzy system techniques and artificial intelligence, which is also known as Adaptive Neuro Fuzzy Interference Systems- ANFIS for improve in terms of quality of electrical energy in supply network. Within the executed experiments there was created a complex adaptive system based on the ANFIS structure. Authors have been examining different structures of the ANFIS network (structure). Experimental results based on real signals are showing up, that mentioned types of control with the use of ANFIS reach very good compensation attributes of the harmonic currents of non-linear load. These control strategies of the active shunt filter are compared on a base of total THD harmonic distortion of current networks after the compensation."@en . "This article is focused on progressive strategies of shunt active performance filters with intension to compensate higher harmonic currents of non-linear load. The authors of this article deal with usage of a combination of fuzzy system techniques and artificial intelligence, which is also known as Adaptive Neuro Fuzzy Interference Systems- ANFIS for improve in terms of quality of electrical energy in supply network. Within the executed experiments there was created a complex adaptive system based on the ANFIS structure. Authors have been examining different structures of the ANFIS network (structure). Experimental results based on real signals are showing up, that mentioned types of control with the use of ANFIS reach very good compensation attributes of the harmonic currents of non-linear load. These control strategies of the active shunt filter are compared on a base of total THD harmonic distortion of current networks after the compensation." . "27240" . . . "Shunt Active Power Filter- SAPF; Power Quality; Total Harmonic Distortion - THD; Adaptive Neuro Fuzzy Inference Systems - ANFIS"@en . . . "RIV/61989100:27240/13:86087277" . "[34807D175CC6]" . . "P(LH12183), S" . "Power Quality Improvement by Shunt Active Performance Filters Emulated by Artificial Intelligence Techniques" . . "Advances in Intelligent Systems Research. Volume 42" . "978-90-78677-70-3" . . "1951-6851" . . "10.2991/cse.2013.37" . "4"^^ . . "Ma\u0148as, Jakub" . "Atlantis Press" . . "Power Quality Improvement by Shunt Active Performance Filters Emulated by Artificial Intelligence Techniques"@en . "000327941200035" . "Bil\u00EDk, Petr" . . . "Power Quality Improvement by Shunt Active Performance Filters Emulated by Artificial Intelligence Techniques" . . . "5"^^ .