"The Periodical and Continual PQ Monitoring of Selected Distribution Networks in Czech Republic"@en . "Bil\u00EDk, Petr" . "The Periodical and Continual PQ Monitoring of Selected Distribution Networks in Czech Republic"@en . . . "[F467806C6264]" . . . . "The Periodical and Continual PQ Monitoring of Selected Distribution Networks in Czech Republic" . "In the power company CEZ in the North Moravia Region (the Czech Republic) the monitoring of a number of selected parameters of the quality of electrical energy (harmonics, flicker and unbalance) is being carried out in cooperation with research laboratories of the Faculty of Electrical Engineering and Computer Science, VSB - Technical University of Ostrava. The monitoring is being carried out in a complex manner in 59 feeding points 400 V, always within one week intervals, and at the same time on all voltage levels (HV, MV and LV). In the paper, the results of the complex monitoring during 12 years will be summarized together with the comparison of the changes of parameters after three years. In addition the results of annual continual monitoring for one selected locality on MV level will be presented in the paper. In addition the possibility of utilization of intelligent electrometers for monitoring of some quality parameters will be referred." . "10.1109/EPQU.2011.6128950" . . . "The Periodical and Continual PQ Monitoring of Selected Distribution Networks in Czech Republic" . . . . . . "219947" . . "978-1-4673-0379-8" . . "RIV/61989100:27240/11:86079241" . "6"^^ . "Lisabon" . "Coimbra" . . . "In the power company CEZ in the North Moravia Region (the Czech Republic) the monitoring of a number of selected parameters of the quality of electrical energy (harmonics, flicker and unbalance) is being carried out in cooperation with research laboratories of the Faculty of Electrical Engineering and Computer Science, VSB - Technical University of Ostrava. The monitoring is being carried out in a complex manner in 59 feeding points 400 V, always within one week intervals, and at the same time on all voltage levels (HV, MV and LV). In the paper, the results of the complex monitoring during 12 years will be summarized together with the comparison of the changes of parameters after three years. In addition the results of annual continual monitoring for one selected locality on MV level will be presented in the paper. In addition the possibility of utilization of intelligent electrometers for monitoring of some quality parameters will be referred."@en . "4"^^ . "4"^^ . "27240" . . "\u010Cumpel\u00EDk, Radim" . "power quality, harmonics, flicker, unbalance"@en . "Z(MSM6198910007)" . "Santarius, Pavel" . . "2011-10-17+02:00"^^ . . . "RIV/61989100:27240/11:86079241!RIV13-MSM-27240___" . "Krej\u010D\u00ED, Petr" . "2150-6647" . . "Institute of Systems and Robotics - University of Coimbra" . "Conference Proceedings of the 11th International Conference IEEE EPQU 2011" .