"Navr\u017Een\u00E9 a realizovan\u00E9 za\u0159\u00EDzen\u00ED pro monitorov\u00E1n\u00ED pohybu pacienta je ur\u010Deno pro m\u011B\u0159en\u00ED vibrac\u00ED pacienta na l\u016F\u017Eku vyvolan\u00FDch ot\u0159esy, kter\u00E9 mohou zp\u016Fsobit nap\u0159. k\u0159e\u010De v p\u0159\u00EDpad\u011B epileptick\u00FDch z\u00E1chvat\u016F. C\u00EDlem za\u0159\u00EDzen\u00ED je poskytnout data s amplitudami ot\u0159es\u016F v re\u00E1ln\u00E9m \u010Dase, kter\u00E9 jsou ur\u010Deny pro p\u0159idru\u017Een\u00ED k ostatn\u00EDm sign\u00E1l\u016Fm, kter\u00E9 se v\u011Bt\u0161inou monitoruj\u00ED p\u0159\u00EDmo na pacientovi a to pomoc\u00ED p\u0159ipojen\u00ED k s\u00E9riov\u00E9mu portu osobn\u00EDho po\u010D\u00EDta\u010De, p\u0159\u00EDpadn\u011B bluetooth za\u0159\u00EDzen\u00ED ve form\u011B osobn\u00EDho po\u010D\u00EDta\u010De nebo mobiln\u00EDho za\u0159\u00EDzen\u00ED, p\u0159\u00EDpadn\u011B za\u0159\u00EDzen\u00ED, kter\u00E9 je schopn\u00E9 komunikovat p\u0159es bluetooth a data zpracov\u00E1vat. Stejn\u00FDm za\u0159\u00EDzen\u00EDm je mo\u017En\u00E9 zpracov\u00E1vat ot\u0159esy pomoc\u00ED diskr\u00E9tn\u00EDch integr\u00E1ln\u00EDch transformac\u00ED a informovat pouze o s\u00EDle ot\u0159es\u016F v p\u0159\u00EDpad\u011B, \u017Ee je nutn\u00E9 dat pos\u00EDlat co nejm\u00E9n\u011B. Prvek je ur\u010Den pro p\u0159ipojen\u00ED k mechanick\u00FDm konstrukc\u00EDm, kde m\u00E1 b\u00FDt sledov\u00E1n pohyb pacienta, roz\u0161i\u0159uje v\u0161ak dosavadn\u00ED konstrukce o bezdr\u00E1tov\u00E9 spojen\u00ED s m\u011B\u0159ic\u00EDm za\u0159\u00EDzen\u00EDm." . . . . . "2"^^ . "accelerometer, epilepsy, detection, movement, measurement system"@en . . "Navr\u017Een\u00E9 a realizovan\u00E9 za\u0159\u00EDzen\u00ED pro monitorov\u00E1n\u00ED pohybu pacienta je ur\u010Deno pro m\u011B\u0159en\u00ED vibrac\u00ED pacienta na l\u016F\u017Eku vyvolan\u00FDch ot\u0159esy, kter\u00E9 mohou zp\u016Fsobit nap\u0159. k\u0159e\u010De v p\u0159\u00EDpad\u011B epileptick\u00FDch z\u00E1chvat\u016F. C\u00EDlem za\u0159\u00EDzen\u00ED je poskytnout data s amplitudami ot\u0159es\u016F v re\u00E1ln\u00E9m \u010Dase, kter\u00E9 jsou ur\u010Deny pro p\u0159idru\u017Een\u00ED k ostatn\u00EDm sign\u00E1l\u016Fm, kter\u00E9 se v\u011Bt\u0161inou monitoruj\u00ED p\u0159\u00EDmo na pacientovi a to pomoc\u00ED p\u0159ipojen\u00ED k s\u00E9riov\u00E9mu portu osobn\u00EDho po\u010D\u00EDta\u010De, p\u0159\u00EDpadn\u011B bluetooth za\u0159\u00EDzen\u00ED ve form\u011B osobn\u00EDho po\u010D\u00EDta\u010De nebo mobiln\u00EDho za\u0159\u00EDzen\u00ED, p\u0159\u00EDpadn\u011B za\u0159\u00EDzen\u00ED, kter\u00E9 je schopn\u00E9 komunikovat p\u0159es bluetooth a data zpracov\u00E1vat. Stejn\u00FDm za\u0159\u00EDzen\u00EDm je mo\u017En\u00E9 zpracov\u00E1vat ot\u0159esy pomoc\u00ED diskr\u00E9tn\u00EDch integr\u00E1ln\u00EDch transformac\u00ED a informovat pouze o s\u00EDle ot\u0159es\u016F v p\u0159\u00EDpad\u011B, \u017Ee je nutn\u00E9 dat pos\u00EDlat co nejm\u00E9n\u011B. Prvek je ur\u010Den pro p\u0159ipojen\u00ED k mechanick\u00FDm konstrukc\u00EDm, kde m\u00E1 b\u00FDt sledov\u00E1n pohyb pacienta, roz\u0161i\u0159uje v\u0161ak dosavadn\u00ED konstrukce o bezdr\u00E1tov\u00E9 spojen\u00ED s m\u011B\u0159ic\u00EDm za\u0159\u00EDzen\u00EDm."@cs . . . "RIV/61989100:27240/10:10223366" . . "RIV/61989100:27240/10:10223366!RIV11-GA0-27240___" . . . "Embedded measuring system for patient's on bed movement detection"@en . "[312A06CAF275]" . "2"^^ . . "Designed and realized device for patient's movement monitoring is dedicated for patient's on the bed vibrations measurement evoked by shaking caused for example with convulsion due epileptic seizures. The aim of this device is to afford a data set with amplitude of vibration in real-time, which are established to affiliate other bio-signals monitored on the patient directly with help of personal computer communication port or blue-tooth serial connection with personal computer or mobile device to process data there.With the same device is possible to process vibrations with discrete integral transformations and to inform about the strength of vibrations in the case of small throughput of data. This device can be put on mechanical contrustion where ht motion of patient should to be observe, presented solution extends current solution with wireless communication with measurement device."@en . "27240" . "Vestav\u011Bn\u00FD m\u011B\u0159ic\u00ED syst\u00E9m pro detekci pohybu pacienta na l\u016F\u017Eku" . . . "Vestav\u011Bn\u00FD m\u011B\u0159ic\u00ED syst\u00E9m pro detekci pohybu pacienta na l\u016F\u017Eku"@cs . "P(GA102/08/1429)" . "Ho\u0159\u00EDnek, Marek" . . "po\u0159izovac\u00ED n\u00E1klady: cca 2000 K\u010D celkov\u011B za hardware" . "Vestav\u011Bn\u00FD m\u011B\u0159ic\u00ED syst\u00E9m pro detekci pohybu pacienta na l\u016F\u017Eku"@cs . . . . "295599" . "Vestav\u011Bn\u00FD m\u011B\u0159ic\u00ED syst\u00E9m pro detekci pohybu pacienta na l\u016F\u017Eku" . "V\u0160B-TUO, Katedra m\u011B\u0159ic\u00ED a \u0159\u00EDdic\u00ED techniky, RC111" . "Slanina, Zden\u011Bk" . "Embedded measuring system for patient's on bed movement detection"@en . . "Z\u00E1kladn\u00ED rozm\u011Bry: 65x130x40 mm, Komunikace RS232/Bluetooth, Zdroj energie: 3xmono\u010Dl\u00E1nek NIHM, intern\u00ED hodiny, n\u00EDzk\u00FD odb\u011Br za\u0159\u00EDzen\u00ED - v\u00FDdr\u017E p\u0159i trval\u00E9m provozu cca 10 dn\u00ED dle kapacity mono\u010Dl\u00E1nku" . . . . . "020/12-04-2010_F" .