. . . "Kapacitn\u00ED elektrody pro bipol\u00E1rn\u00ED m\u011B\u0159en\u00ED EKG."@cs . "RIV/61989100:27230/14:86090111" . "Kapacitn\u00ED elektrody pro bipol\u00E1rn\u00ED m\u011B\u0159en\u00ED EKG." . "Capacity electrodes for unipolar measurement of EKG"@en . . . "Kijonka, Jan" . . "23949" . . "measurements; ECG"@en . "1"^^ . "[9E4367F7F519]" . "Za\u0159\u00EDzen\u00ED bylo navr\u017Eeno a vyrobeno za \u00FA\u010Delem v\u00FDzkumu v oblasti m\u011B\u0159en\u00ED tepov\u00E9 frekvence u hasi\u010D\u016F." . "RIV/61989100:27230/14:86090111!RIV15-MSM-27230___" . . "1"^^ . "Nap\u00E1jec\u00ED nap\u011Bt\u00ED: +-9V, 5mA / elektroda. V\u00FDstup: analogov\u00FD s amplitudou asi 4 mV. Pro spr\u00E1vnou funkci opera\u010Dn\u00EDch zesilova\u010D\u016F je nutn\u00E9 bipol\u00E1rn\u00ED nap\u00E1jen\u00ED. To lze z\u00EDskat tak\u00E9 z Li-ion baterie 3,7V pomoc\u00ED n\u00E1sobi\u010D\u016F a negativn\u00EDho konvertoru nap\u011Bt\u00ED." . "Capacity electrodes for unipolar measurement of EKG"@en . . "27230" . "086/04-11-2014_F" . . . . "Kapacitn\u00ED elektrody pro bipol\u00E1rn\u00ED m\u011B\u0159en\u00ED EKG."@cs . "Tyto elektrody umo\u017E\u0148uj\u00ED kapacitn\u00ED m\u011B\u0159en\u00ED EKG s c\u00EDlem zpracov\u00E1n\u00ED m\u011B\u0159en\u00FDch dat a vyhodnocen\u00ED parametr\u016F v\u010Detn\u011B srde\u010Dn\u00EDho tepu z k\u0159ivky EKG. Bipol\u00E1rn\u00ED m\u011B\u0159en\u00ED prob\u00EDh\u00E1 pomoc\u00ED dvou elektrod, kdy jedna m\u011B\u0159\u00EDc\u00ED elektroda je um\u00EDst\u011Bna v bl\u00EDzkosti sterna a druh\u00E1 na lev\u00E9m boku. Takto z\u00EDsk\u00E1me nejvy\u0161\u0161\u00ED m\u011B\u0159en\u00FD potenci\u00E1l EKG. Elektrody v\u010Detn\u011B speci\u00E1ln\u00EDch p\u0159\u00EDvodn\u00EDch vodi\u010D\u016F v\u0161it\u00FDch do l\u00E1tky jsou um\u00EDst\u011Bny z vnit\u0159n\u00ED strany elastick\u00E9ho trika a st\u00EDn\u011Bny vodivou l\u00E1tkou. Mezi k\u016F\u017E\u00ED a elektrodou je tenk\u00E1 tkanina z bavlny. Aktivn\u00ED elektrodu RLD tvo\u0159\u00ED kus vodiv\u00E9 l\u00E1tky. V\u00FDhodou kapacitn\u00EDho zp\u016Fsobu m\u011B\u0159en\u00ED je bezkontaktn\u00ED sn\u00EDm\u00E1n\u00ED vhodn\u00E9 pro dlouhodob\u00E9 m\u011B\u0159en\u00ED a rychl\u00E1 aplikace sn\u00EDma\u010D\u016F. Pomoc\u00ED bipol\u00E1rn\u00EDho m\u011B\u0159en\u00ED je mo\u017En\u00E9 z\u00EDskat kvalitn\u00ED sign\u00E1l s dostate\u010Dn\u00FDm potla\u010Den\u00EDm souf\u00E1zov\u00E9 slo\u017Eky."@cs . "V" . . "Kapacitn\u00ED elektrody pro bipol\u00E1rn\u00ED m\u011B\u0159en\u00ED EKG." . "Tyto elektrody umo\u017E\u0148uj\u00ED kapacitn\u00ED m\u011B\u0159en\u00ED EKG s c\u00EDlem zpracov\u00E1n\u00ED m\u011B\u0159en\u00FDch dat a vyhodnocen\u00ED parametr\u016F v\u010Detn\u011B srde\u010Dn\u00EDho tepu z k\u0159ivky EKG. Bipol\u00E1rn\u00ED m\u011B\u0159en\u00ED prob\u00EDh\u00E1 pomoc\u00ED dvou elektrod, kdy jedna m\u011B\u0159\u00EDc\u00ED elektroda je um\u00EDst\u011Bna v bl\u00EDzkosti sterna a druh\u00E1 na lev\u00E9m boku. Takto z\u00EDsk\u00E1me nejvy\u0161\u0161\u00ED m\u011B\u0159en\u00FD potenci\u00E1l EKG. Elektrody v\u010Detn\u011B speci\u00E1ln\u00EDch p\u0159\u00EDvodn\u00EDch vodi\u010D\u016F v\u0161it\u00FDch do l\u00E1tky jsou um\u00EDst\u011Bny z vnit\u0159n\u00ED strany elastick\u00E9ho trika a st\u00EDn\u011Bny vodivou l\u00E1tkou. Mezi k\u016F\u017E\u00ED a elektrodou je tenk\u00E1 tkanina z bavlny. Aktivn\u00ED elektrodu RLD tvo\u0159\u00ED kus vodiv\u00E9 l\u00E1tky. V\u00FDhodou kapacitn\u00EDho zp\u016Fsobu m\u011B\u0159en\u00ED je bezkontaktn\u00ED sn\u00EDm\u00E1n\u00ED vhodn\u00E9 pro dlouhodob\u00E9 m\u011B\u0159en\u00ED a rychl\u00E1 aplikace sn\u00EDma\u010D\u016F. Pomoc\u00ED bipol\u00E1rn\u00EDho m\u011B\u0159en\u00ED je mo\u017En\u00E9 z\u00EDskat kvalitn\u00ED sign\u00E1l s dostate\u010Dn\u00FDm potla\u010Den\u00EDm souf\u00E1zov\u00E9 slo\u017Eky." . . . "These electrodes allow capacitive ECG measurements in order to process the measured data and evaluation of parameters including heart rate from the ECG waveform. Bipolar measuring is performed by two electrodes where one measuring electrode is placed near the sternum, and second on the left side. Thus we get the highest measured potential ECG. Electrodes including special wires sewn into the fabric are placed on the inside of the elastic T-shirts and shielded conductive material. Between the skin and the electrode is a thin woven fabric made of cotton. Active RLD electrode forming a piece of conductive material. The advantage of the capacitive measurement method is suitable for contactless detection of long-term measurement and rapid application of the sensors. With the bipolar measurement is possible to get good quality signal with sufficient suppression of phase components."@en . .