. "RIV/61389021:_____/06:00043564!RIV07-AV0-61389021" . "\u017D\u00E1\u010Dek, Franti\u0161ek" . "NBI system for reinstalled COMPASS{D tokamak"@en . "NBI system for reinstalled COMPASS{D tokamak" . . "12"^^ . "6"^^ . "CZ - \u010Cesk\u00E1 republika" . "[E39CD042390D]" . . . "COMPASS-D tokamak, originally operated by UKAEA at Culham, UK, will be re-installed at the Institute of Plasma Physics AS CR. As the major upgrade, apart from many new diagnostics, a new neutral beam injection (NBI) system will be installed. Two beams, each with 40 keV particle energy and 300 kW peak power, will provide routine access to H-mode operation. Possible scenarios of NBI heating are discussed. Co- and counter- injections are considered, as well as on-axis and off-axis beam aiming." . "Fuchs, Vladim\u00EDr" . "176;181" . . . "Z(AV0Z20430508)" . . "Czechoslovak Journal of Physics" . "Simulace EBW a porovn\u00E1n\u00ED s p\u0159edb\u011B\u017En\u00FDmi v\u00FDsledky z NSTX"@cs . "Tokamak COMPASS-D, kter\u00FD byl provozov\u00E1n v UKAEA Culham, UK, bude p\u0159evezen do \u00DAstavu fyziky plazmatu, AV \u010CR. Krom\u011B nov\u00E9 diagnostiky, hlavn\u00ED vylep\u0161en\u00ED p\u0159edstavuje nov\u00FD syst\u00E9m vst\u0159iku neutr\u00E1ln\u00EDho svazku (NBI). Dva svazky, ka\u017Ed\u00FD s energii \u010D\u00E1stic 40 keV a s maxim\u00E1ln\u00EDm v\u00FDkonem 300 kW, budou umo\u017E\u0148ovat snadn\u00E9 dosa\u017Een\u00ED H-\u00B4m\u00F3du v pr\u016Fb\u011Bhu v\u00FDboje. Byly studov\u00E1ny r\u016Fzn\u00E1 uspo\u0159\u00E1d\u00E1n\u00ED oh\u0159evu. Uva\u017Eoval se souhlasn\u00FD a protich\u016Fdn\u00FD vst\u0159ik a rovn\u011B\u017E osov\u00FD i mimo osov\u00FD pr\u016Fchod svazku."@cs . . . "488005" . . "NBI system for reinstalled COMPASS{D tokamak" . . . . "RIV/61389021:_____/06:00043564" . . . "St\u00F6ckel, Jan" . . "Preinhaelter, Josef" . "Simulace EBW a porovn\u00E1n\u00ED s p\u0159edb\u011B\u017En\u00FDmi v\u00FDsledky z NSTX"@cs . "56" . "Urban, Jakub" . "COMPASS-D tokamak, originally operated by UKAEA at Culham, UK, will be re-installed at the Institute of Plasma Physics AS CR. As the major upgrade, apart from many new diagnostics, a new neutral beam injection (NBI) system will be installed. Two beams, each with 40 keV particle energy and 300 kW peak power, will provide routine access to H-mode operation. Possible scenarios of NBI heating are discussed. Co- and counter- injections are considered, as well as on-axis and off-axis beam aiming."@en . "NBI system for reinstalled COMPASS{D tokamak"@en . "0011-4626" . . "suppl.B" . "COMPASS-D; NBI"@en . . "8"^^ . "Mishagin, V. V." . "Davydenko, V. I." . . "P\u00E1nek, Radom\u00EDr" .