"Anal\u00FDza kontaktn\u00EDch tlak\u016F mezi \u010D\u00E1stmi tot\u00E1ln\u00ED ky\u010Deln\u00ED endoprot\u00E9za s tvarov\u00FDmi odchylkami"@cs . . "Koukal, M." . "Hlavo\u0148, Pavel" . "Analysis of contact pressure between the parts of total hip joint endoprosthesis with shape deviations" . "Analysis of contact pressure between the parts of total hip joint endoprosthesis with shape deviations"@en . . "5"^^ . . . "Fuis, Vladim\u00EDr" . "V \u010Dl\u00E1nku jsou analyzov\u00E1ny dva klinick\u00E9 probl\u00E9my ky\u010Deln\u00EDch endoprot\u00E9z t\u00FDkaj\u00EDc\u00EDch se tvarov\u00FDch odchylek kontaktn\u00EDch ploch (d\u0159\u00EDk hlavice a d\u0159\u00EDku nebo kulov\u00E9 plochy hlavice a jamky), kter\u00E9 byly \u0159e\u0161eny v\u00FDpo\u010Dtov\u00FDm modelov\u00E1n\u00EDm. Z v\u00FDsledk\u016F modelov\u00E1n\u00ED vypl\u00FDv\u00E1, \u017Ee makrotvarov\u00E9 a mikrotvarov\u00E9 odchylky kontaktn\u00EDch ploch v\u00FDrazn\u011B ovliv\u0148uj\u00ED napjatost a spolehlivost endorpot\u00E9z."@cs . "1"^^ . . "0021-9290" . . "Analysis of contact pressure between the parts of total hip joint endoprosthesis with shape deviations" . "Two clinical problems of the hip joint endoprosthesis that were caused by the shape deviation of the contact areas (head and stem cones or head and cup spheres) were solved using computational modelling. The macro-shape and micro-shape deviations of the contacted pairs significantly influenced the contact pressure distribution and generally the stress fields in the endoprosthesis components."@en . "N\u00E1vrat, Tom\u00E1\u0161" . . . . "Analysis of contact pressure between the parts of total hip joint endoprosthesis with shape deviations"@en . "[49042F16B433]" . "Two clinical problems of the hip joint endoprosthesis that were caused by the shape deviation of the contact areas (head and stem cones or head and cup spheres) were solved using computational modelling. The macro-shape and micro-shape deviations of the contacted pairs significantly influenced the contact pressure distribution and generally the stress fields in the endoprosthesis components." . "GB - Spojen\u00E9 kr\u00E1lovstv\u00ED Velk\u00E9 Brit\u00E1nie a Severn\u00EDho Irska" . . "2" . . "409455" . "S558;S558" . . "RIV/61388998:_____/07:00086790" . . . "Journal of Biomechanics" . "shape deviation; hip joint endoprosthesis; contact areas"@en . . "P(GA101/05/0136), Z(AV0Z20760514)" . "Houfek, Martin" . "RIV/61388998:_____/07:00086790!RIV08-AV0-61388998" . . "4"^^ . . "Anal\u00FDza kontaktn\u00EDch tlak\u016F mezi \u010D\u00E1stmi tot\u00E1ln\u00ED ky\u010Deln\u00ED endoprot\u00E9za s tvarov\u00FDmi odchylkami"@cs . . "40" . . .