"6" . "RIV/60461373:22330/04:00012782!RIV/2005/MSM/223305/N" . "Ur\u010Den\u00ED z\u00E1kladn\u00ED zd\u00E1nliv\u00E9 linie jako svalov\u00E9ho pozad\u00ED pro stanoven\u00ED myoglobinu reflek\u010Dn\u00ED spektrometri\u00ED"@cs . . "Z(MSM 223300004)" . "7"^^ . "Estimation of the base line imagined as a muscular background for myoglobin determination by reflectance spectrometry" . . "Izumimoto, M." . . "Ur\u010Den\u00ED z\u00E1kladn\u00ED zd\u00E1nliv\u00E9 linie jako svalov\u00E9ho pozad\u00ED pro stanoven\u00ED myoglobinu reflek\u010Dn\u00ED spektrometri\u00ED"@cs . "Liquid extraction method for determination of Mb in muscle is not suitable due to changes in the derivatives and time required. Optical reflectance method is useful as a non-destructive and real-time measurement. However, the base line of reflectance method, the muscular reflectance background (MRB) imagined as colorless structural elements, has been unknown due to non-existence. The spectrum of the base line was analyzed as the analogy of bleached meat. A formula was derived for reflectance which had a linear relationship to the reciprocal of wavelength to the power 4. The reflectance characteristic of the MRB was not constant and the curve tended to rise with increasing wavelength. The reflectance at 700 nm was estimated to be 50 %. By the characteristic analysis on CIE color values and reciprocal reflectance, it was concluded that the reflectance spectrum of the muscular background obtained in this research was fitted as a base line for the reflectance spectrometry."@en . "Liquid extraction method for determination of Mb in muscle is not suitable due to changes in the derivatives and time required. Optical reflectance method is useful as a non-destructive and real-time measurement. However, the base line of reflectance method, the muscular reflectance background (MRB) imagined as colorless structural elements, has been unknown due to non-existence. The spectrum of the base line was analyzed as the analogy of bleached meat. A formula was derived for reflectance which had a linear relationship to the reciprocal of wavelength to the power 4. The reflectance characteristic of the MRB was not constant and the curve tended to rise with increasing wavelength. The reflectance at 700 nm was estimated to be 50 %. By the characteristic analysis on CIE color values and reciprocal reflectance, it was concluded that the reflectance spectrum of the muscular background obtained in this research was fitted as a base line for the reflectance spectrometry." . "563186" . . "1344-3941" . "Estimation of the base line imagined as a muscular background for myoglobin determination by reflectance spectrometry" . . . . . . . "Pipek, Petr" . "22330" . "Estimation of the base line imagined as a muscular background for myoglobin determination by reflectance spectrometry"@en . "Yonehara, M." . "Animal Science Journal" . . "3"^^ . . "563-569" . . "1"^^ . . "Extrak\u010Dn\u00ED metoda stanoven\u00ED Mb ve svalovin\u011B nen\u00ED vhodn\u00E1 vzhledem ke zm\u011Bn\u00E1m deriv\u00E1t\u016F a pot\u0159eb\u011B \u010Dasu. Optick\u00E1 reflek\u010Dn\u00ED metoda je vhodn\u00E1 jako nedestruktivn\u00ED, av\u0161ak z\u00E1kladn\u00ED linie reflektance (MRB) p\u0159edstaven\u00E1 jako bezbarv\u00FD struktur\u00E1ln\u00ED element je nezn\u00E1m\u00E1 a neexistuje. Spektrum z\u00E1kladn\u00ED linie bylo analyzov\u00E1no z analogie s vyb\u011Blen\u00FDm masem. Reflektance p\u0159i 700 nm je uva\u017Eov\u00E1na jako 50 %. Anal\u00FDzou charakteristik CIE barvy a p\u0159evr\u00E1cen\u00E9 hodnoty reflektance se do\u0161lo k z\u00E1v\u011Bru, \u017Ee reflek\u010Dn\u00ED spektrum svalov\u00E9ho z\u00E1kladu se shoduje se z\u00E1kladn\u00ED lini\u00ED reflek\u010Dn\u00ED spektrometrie."@cs . . "JP - Japonsko" . "RIV/60461373:22330/04:00012782" . "[A6C1116ED0B1]" . . "Estimation of the base line imagined as a muscular background for myoglobin determination by reflectance spectrometry"@en . "Reflectance spectrum;Myoglobin determination;Reflectance background;Muscle;Meat"@en . "75" . .