"Is it possible to measure diameters of metal nanoparticles using BSE imaging in FESEM?" . "The possibilities of using a field emission scanning electron microscope (FESEM) equipped with an Autrata improved yttrium aluminum garnet (YAG) detector of back-scattered electrons (BSE) for a determination of metal nanoparticles sizes were examined in this study. The diameters of Au and Pd nanoparticles with different sizes were resolved based on digitally recorded FESEM micrographs and were compared with diameters obtained with a transmission electron microscope (TEM). In the case of Au nanoparticles, the data obtained from the FESEM exhibited smaller values in comparison with data from the TEM. The Pd nanoparticles diameters measured in the FESEM were comparable with those determined by means of the TEM, however. The influence of various parameters like the sizes of nanoparticles, their composition, use of accelerating voltage and other working conditions in the FESEM on the measurement results are discussed."@en . . "8"^^ . . . "GB - Spojen\u00E9 kr\u00E1lovstv\u00ED Velk\u00E9 Brit\u00E1nie a Severn\u00EDho Irska" . . "The possibilities of using a field emission scanning electron microscope (FESEM) equipped with an Autrata improved yttrium aluminum garnet (YAG) detector of back-scattered electrons (BSE) for a determination of metal nanoparticles sizes were examined in this study. The diameters of Au and Pd nanoparticles with different sizes were resolved based on digitally recorded FESEM micrographs and were compared with diameters obtained with a transmission electron microscope (TEM). In the case of Au nanoparticles, the data obtained from the FESEM exhibited smaller values in comparison with data from the TEM. The Pd nanoparticles diameters measured in the FESEM were comparable with those determined by means of the TEM, however. The influence of various parameters like the sizes of nanoparticles, their composition, use of accelerating voltage and other working conditions in the FESEM on the measurement results are discussed." . "Langhans, Jan" . "44" . . "Vancov\u00E1, Marie" . "RIV/60077344:_____/13:00397203" . . . "5"^^ . . "Nebes\u00E1\u0159ov\u00E1, Jana" . "I, P(GAP205/10/0348), P(KAN200520704), V" . "\u0160louf, Miroslav" . . "0968-4328" . "Micron" . . "Is it possible to measure diameters of metal nanoparticles using BSE imaging in FESEM?" . "JAN 2013" . "Au nanoparticles; Autrata YAG detector of BSE signal; FESEM; Pd nanoparticles; Size measurement"@en . . . "[1634AD9B6558]" . . . "3"^^ . "Is it possible to measure diameters of metal nanoparticles using BSE imaging in FESEM?"@en . "81264" . . "Is it possible to measure diameters of metal nanoparticles using BSE imaging in FESEM?"@en . . . "RIV/60077344:_____/13:00397203!RIV14-AV0-60077344" . . "000312925300015" . . . "Pavlova, Ewa" . . . "10.1016/j.micron.2012.06.002" . .