"\u010Cl\u00E1nek je zam\u011B\u0159en na srovn\u00E1vac\u00ED diagnostiku mikrovlnn\u00E9ho plazmatu, generovan\u00E9ho surfatronem, kde Ar a He p\u0159edstavuj\u00ED nosn\u00FD plyn a N2 je pou\u017Eit jako reaktivn\u00ED p\u0159\u00EDm\u011Bs. Diagnostikovan\u00FD mikrovlnn\u00FD zdroj je p\u0159edstavov\u00E1n surfatronem nap\u00E1jen\u00FDm mikrovlnn\u00FDm zdrojem pracuj\u00EDc\u00EDm s frekvenc\u00ED 2.45 GHz s v\u00FDstupn\u00EDm v\u00FDkonem v rozsahu 0-300 W, kter\u00FD generuje plazma z proud\u00EDc\u00EDho plynu v k\u0159emenn\u00E9 trubici. Rychlost proud\u00EDc\u00EDho plynu je konstantn\u00ED (obvykle 600 sccm), ale pom\u011Br reaktivn\u00EDho plynu je m\u011Bn\u011Bn. V \u010Dl\u00E1nku jsou prezentov\u00E1ny n\u011Bkter\u00E9 v\u00FDsledky diagnostiky generovan\u00E9ho plazmatu ho\u0159\u00EDc\u00EDho uvnit\u0159 trubice i v trubici v z\u00E1vislosti na r\u016Fzn\u00FDch experiment\u00E1ln\u00EDch podm\u00EDnk\u00E1ch: prom\u011Bnn\u00FD absorbovan\u00FD v\u00FDkon, tlak v pracovn\u00ED komo\u0159e atd. Diagnostika plazmatu byla provedena pomoc\u00ED m\u011B\u0159en\u00ED s dvojic\u00ED sond (elektronov\u00E1 teplota vypo\u010Dten\u00E1 z nam\u011B\u0159en\u00FDch dat) a pomoc\u00ED optick\u00E9 emisn\u00ED spektroskopie (rota\u010Dn\u00ED a vibra\u010Dn\u00ED teploty, odhad chemick\u00E9ho slo\u017Een\u00ED v\u00FDboje z p\u0159ehledov\u00E9ho spektra)."@cs . "Nice, France" . . "Cadarache" . . . "Comparative diagnostics of Ar and He surfatron generated plasma by means of optical emission spectroscopy and probe measurements" . . "7"^^ . . "[BC55855D360C]" . . . "Srovn\u00E1c\u00ED diagnostika surfatrov\u00E9ho v\u00FDboje v Ar a He pomoc\u00ED optick\u00E9 emisn\u00ED spektroskopie a sondov\u00FDch m\u011B\u0159en\u00ED"@cs . . "The article is focused on comparative diagnostics of microwave plasmas, generated by surfatron, where Ar and He are used as carrier gases N2 is used as reactive gas. The diagnosed microwave-driven plasma source consists of a surfatron powered by a microwave magnetron generator, working at frequency 2.45 GHz in the output power range 0-300 W, which creates plasma from the flowing working gas in a quartz nozzle. The gas flow rate is kept typically constant at 600 sccm but ratio of carrier gas and reactive gas is varied. We present some results of diagnostics of generated plasma at nozzle exit as well as in the nozzle at different experimental conditions: variable absorbed power, total chamber pressure etc. The diagnostics of plasma column was performed by means of double probe measurement (mainly electron temperature is calculated from measured data) and by optical emission spectroscopy (rotational and vibrational temperatures, estimation of plasma composition from overview spectra)."@en . . "\u0160er\u00FD, Michal" . . "In: HAL (Hyper Article on Line) (http://hal.ccsd.cnrs.fr/docs/00/00/25/06/PDF/ICPP2004.pdf, e-Proc. of 12th ICPP" . "Srovn\u00E1c\u00ED diagnostika surfatrov\u00E9ho v\u00FDboje v Ar a He pomoc\u00ED optick\u00E9 emisn\u00ED spektroskopie a sondov\u00FDch m\u011B\u0159en\u00ED"@cs . . "4"^^ . . . "12410" . "RIV/60076658:12410/04:00005562!RIV/2005/MSM/124105/N" . "Comparative diagnostics of Ar and He surfatron generated plasma by means of optical emission spectroscopy and probe measurements"@en . "2004-10-25+02:00"^^ . . "-" . "Comparative diagnostics of Ar and He surfatron generated plasma by means of optical emission spectroscopy and probe measurements" . "6"^^ . "Trunec, D." . . "\u0160patenka, Petr" . "Slav\u00ED\u010Dek, P." . "The article is focused on comparative diagnostics of microwave plasmas, generated by surfatron, where Ar and He are used as carrier gases N2 is used as reactive gas. The diagnosed microwave-driven plasma source consists of a surfatron powered by a microwave magnetron generator, working at frequency 2.45 GHz in the output power range 0-300 W, which creates plasma from the flowing working gas in a quartz nozzle. The gas flow rate is kept typically constant at 600 sccm but ratio of carrier gas and reactive gas is varied. We present some results of diagnostics of generated plasma at nozzle exit as well as in the nozzle at different experimental conditions: variable absorbed power, total chamber pressure etc. The diagnostics of plasma column was performed by means of double probe measurement (mainly electron temperature is calculated from measured data) and by optical emission spectroscopy (rotational and vibrational temperatures, estimation of plasma composition from overview spectra)." . . "RIV/60076658:12410/04:00005562" . "Stra\u0148\u00E1k, V\u00EDt\u011Bzslav" . "Association Euratom-CEA" . "558153" . . . "optical emission spectroscopy;surfatron;2.45 GHz;argon;helium"@en . "Z(MSM 124100004)" . "Tich\u00FD, Milan" . . . . "Navr\u00E1til, Z." . "Comparative diagnostics of Ar and He surfatron generated plasma by means of optical emission spectroscopy and probe measurements"@en .