. . "Tesa\u0159ov\u00E1, Miloslava" . "23220" . "distribution system, power quality, voltage dip, sag, interruption, voltage event, fault statistics"@en . "P\u0159\u00EDpadov\u00E1 studie stanoven\u00ED po\u010Dtu pokles\u016F nap\u011Bt\u00ED v distribu\u010Dn\u00ED s\u00EDti 110kV"@cs . "P\u0159\u00EDsp\u011Bvek se zab\u00FDv\u00E1 problematikou stanoven\u00ED po\u010Dtu pokles\u016F nap\u011Bt\u00ED v distribu\u010Dn\u00ED s\u00EDti. V \u00FAvodu jsou pops\u00E1ny siln\u00E9 a slab\u00E9 str\u00E1nky monitorov\u00E1n\u00ED pokles\u016F nap\u011Bt\u00ED a v\u00FDpo\u010Detn\u00EDch metod pro predikci o\u010Dek\u00E1van\u00E9ho po\u010Dtu pokles\u016F, kter\u00E9 jsou zalo\u017Een\u00E9 na vyhodnocov\u00E1n\u00ED historick\u00FDch dat. Oba zp\u016Fsoby stanoven\u00ED pokles\u016F nap\u011Bt\u00ED jsou aplikov\u00E1ny v p\u0159\u00EDpadov\u00E9 studii na konkr\u00E9tn\u00ED uzlov\u00E9 oblasti 110kV. Na z\u00E1klad\u011B historick\u00FDch dat z trvale instalo-van\u00E9ho analyz\u00E1toru kvality nap\u011Bt\u00ED (data z let 2006-2010) jsou vyhodnoceny re\u00E1ln\u00E9 zm\u011B\u0159en\u00E9 po\u010Dty pokles\u016F. Do v\u00FDpo\u010Detn\u00EDho modelu jsou dosazeny \u00FAdaje o poruchovosti s\u00EDt\u011B 110kV z\u00EDskan\u00E9 anal\u00FDzou historick\u00FDch dat z informa\u010Dn\u00EDho syst\u00E9mu spole\u010Dnosti E.ON. V\u00FDsledky v\u00FDpo\u010Detn\u00EDho modelu jsou porovn\u00E1ny s v\u00FDsledky m\u011B\u0159en\u00ED a na jejich z\u00E1klad\u011B je provedena diskuze vyu\u017Eit\u00ED obou zp\u016Fsob\u016F stanoven\u00ED po\u010Dtu pokles\u016F nap\u011Bt\u00ED." . . . . . . "The paper deals with determining the number of voltage dips in the distribution network. The introduction describes the strengths and weaknesses of the monitoring voltage dips and the calculation methods for predicting the expected number of dips, which are based on the evaluation of historical data. Both methods of determining voltage dips are applied in the case study on a particular node area of 110kV. Based on the historical data from the permanently installed voltage quality analyzer (data 2006-2010) there are evaluated the actual measured numbers of dips. The calculation model is substituted by data about 110kV network failure acquired by the analysis of the historical data from the E.ON information system. The results of the calculation model are compared with the measurement results and on the basis of these results the use of both methods of determining the number of voltage dips is discussed."@en . . . . . "I" . "RIV/49777513:23220/12:43916554!RIV13-MSM-23220___" . "Case of study - The voltage dip assessment in a 110 kV distribution network"@en . "[C09E3EFF1522]" . . "P\u0159\u00EDpadov\u00E1 studie stanoven\u00ED po\u010Dtu pokles\u016F nap\u011Bt\u00ED v distribu\u010Dn\u00ED s\u00EDti 110kV" . . "Ka\u0161p\u00EDrek, Martin" . "P\u0159\u00EDpadov\u00E1 studie stanoven\u00ED po\u010Dtu pokles\u016F nap\u011Bt\u00ED v distribu\u010Dn\u00ED s\u00EDti 110kV"@cs . "RIV/49777513:23220/12:43916554" . "Case of study - The voltage dip assessment in a 110 kV distribution network"@en . . . "P\u0159\u00EDsp\u011Bvek se zab\u00FDv\u00E1 problematikou stanoven\u00ED po\u010Dtu pokles\u016F nap\u011Bt\u00ED v distribu\u010Dn\u00ED s\u00EDti. V \u00FAvodu jsou pops\u00E1ny siln\u00E9 a slab\u00E9 str\u00E1nky monitorov\u00E1n\u00ED pokles\u016F nap\u011Bt\u00ED a v\u00FDpo\u010Detn\u00EDch metod pro predikci o\u010Dek\u00E1van\u00E9ho po\u010Dtu pokles\u016F, kter\u00E9 jsou zalo\u017Een\u00E9 na vyhodnocov\u00E1n\u00ED historick\u00FDch dat. Oba zp\u016Fsoby stanoven\u00ED pokles\u016F nap\u011Bt\u00ED jsou aplikov\u00E1ny v p\u0159\u00EDpadov\u00E9 studii na konkr\u00E9tn\u00ED uzlov\u00E9 oblasti 110kV. Na z\u00E1klad\u011B historick\u00FDch dat z trvale instalo-van\u00E9ho analyz\u00E1toru kvality nap\u011Bt\u00ED (data z let 2006-2010) jsou vyhodnoceny re\u00E1ln\u00E9 zm\u011B\u0159en\u00E9 po\u010Dty pokles\u016F. Do v\u00FDpo\u010Detn\u00EDho modelu jsou dosazeny \u00FAdaje o poruchovosti s\u00EDt\u011B 110kV z\u00EDskan\u00E9 anal\u00FDzou historick\u00FDch dat z informa\u010Dn\u00EDho syst\u00E9mu spole\u010Dnosti E.ON. V\u00FDsledky v\u00FDpo\u010Detn\u00EDho modelu jsou porovn\u00E1ny s v\u00FDsledky m\u011B\u0159en\u00ED a na jejich z\u00E1klad\u011B je provedena diskuze vyu\u017Eit\u00ED obou zp\u016Fsob\u016F stanoven\u00ED po\u010Dtu pokles\u016F nap\u011Bt\u00ED."@cs . . "2"^^ . . "161798" . "2"^^ . . . "P\u0159\u00EDpadov\u00E1 studie stanoven\u00ED po\u010Dtu pokles\u016F nap\u011Bt\u00ED v distribu\u010Dn\u00ED s\u00EDti 110kV" . .