. . "The paper describes results of the simulational testing of the system with variable structure in nominal and not nominal operation regimes. The digital control system with switching estimators is tuned for two nominal regimes with the affinity coefficients KE = 1 and KE = 2. The transfer function of the continuous controlled system model is changed in the range of the values of the affinity coefficient KS from 0.7 to 2.8 (in relation 1:4). The unmeasurable step disturbances enter the controlled system model during the testing."@en . . "2"^^ . "\u0158\u00EDzen\u00ED v\u00EDcerozm\u011Brov\u00FDch syst\u00E9m\u016F pomoc\u00ED p\u0159ep\u00EDnan\u00FDch regul\u00E1tor\u016F"@cs . "2006-06-13+02:00"^^ . "V p\u0159\u00EDp\u011Bvku jsou uvedeny v\u00FDsledky simula\u010Dn\u00EDch v\u00FDpo\u010Dt\u016F pro ov\u011B\u0159en\u00ED algoritmu \u0159\u00EDzen\u00ED s p\u0159ep\u00EDnan\u00FDmi regul\u00E1tory a estim\u00E1tory. Zvoleny jsou dva \u010Dasov\u011B afinn\u00ED nomin\u00E1ln\u00ED re\u017Eimy soustavy s odpov\u00EDdaj\u00EDc\u00EDmi estim\u00E1tory (koeficienty affinity KE = 1 a KE = 2). Pro p\u0159enos spojit\u00E9 regulovan\u00E9 soustavy se pak b\u011Bhem simulace m\u011Bn\u00ED koeficient \u010Dasov\u00E9 affinity v rozmez\u00ED hodnot 0.7 a\u017E 2.8. Je tak\u00E9 uva\u017Eov\u00E1n vstup nem\u011B\u0159iteln\u00E9 poruchy b\u011Bhem regula\u010Dn\u00EDho procesu."@cs . "The multivariable control system with switching estimators"@en . "The multivariable control system with switching estimators"@en . "2"^^ . "[B859D5CD38ED]" . . . "49" . "The multivariable control system with switching estimators" . . "Pardubice" . . "80-7194-860-8" . . "The paper describes results of the simulational testing of the system with variable structure in nominal and not nominal operation regimes. The digital control system with switching estimators is tuned for two nominal regimes with the affinity coefficients KE = 1 and KE = 2. The transfer function of the continuous controlled system model is changed in the range of the values of the affinity coefficient KS from 0.7 to 2.8 (in relation 1:4). The unmeasurable step disturbances enter the controlled system model during the testing." . "P(GA101/04/1182)" . "24220" . . "RIV/46747885:24220/06:@0000211!RIV07-GA0-24220___" . . "\u0158\u00EDzen\u00ED v\u00EDcerozm\u011Brov\u00FDch syst\u00E9m\u016F pomoc\u00ED p\u0159ep\u00EDnan\u00FDch regul\u00E1tor\u016F"@cs . . . "1"^^ . "RIV/46747885:24220/06:@0000211" . "Proceedings the 7th International Scientific-Technical Conference PROCESS CONTROL 2006" . "487339" . "T\u016Fma, Libor" . . . . "Hanu\u0161, Bo\u0159ivoj" . "%22Variable structure control; controller; estimator; estimator error; switching%22"@en . "Univerzita Pardubice" . "Kouty nad Desnou, Czech Republic" . "The multivariable control system with switching estimators" . . . . .