"Na Hroud\u011B 1492/4 100 05, Praha 10" . "\u010Cesk\u00FD komit\u00E9t CIRED" . . "4"^^ . "Refer\u00E1ty konference \u010CK CIRED 2012" . . "978-80-905014-1-6" . "26220" . "Ors\u00E1gov\u00E1, Jaroslava" . . . "RIV/00216305:26220/12:PU100660" . "The paper deals with the description and analysis of the method of the additional earthing of the affected phase used for the elimination of the fault current during an earth fault in a compensated network."@en . . . . "P\u0159\u00EDsp\u011Bvek je zam\u011B\u0159en na vyhodnocen\u00ED dotykov\u00E9ho nap\u011Bt\u00ED, kter\u00E9 bylo zaznamen\u00E1no b\u011Bhem s\u00E9rie experimen-t\u00E1ln\u00EDch m\u011B\u0159en\u00ED v kompenzovan\u00E9 distribu\u010Dn\u00ED soustav\u011B 22 kV, kter\u00E9 jsou vybaveny automatikou p\u0159izemn\u011Bn\u00ED posti\u017Een\u00E9 f\u00E1ze. B\u011Bhem experimentu bylo um\u011Ble vyvol\u00E1v\u00E1no kovov\u00E9 zemn\u00ED spojen\u00ED uvnit\u0159 vybran\u00FDch distri-bu\u010Dn\u00EDch trafostanic. Testov\u00E1ny byly dva rozsahy distribu\u010Dn\u00ED soustavy. Z\u00E1kladn\u00ED rozsah 300A, kter\u00FD je dle \u010Desk\u00FDch norem limitn\u00ED pro provoz sm\u00ED\u0161en\u00E9 DS a rozsah 800A, kter\u00FD je maxim\u00E1ln\u00ED rozsah testovan\u00E9 soustavy. V p\u0159\u00EDsp\u011Bvku bude zhodnocena \u00FArove\u0148 dotykov\u00E9ho nap\u011Bt\u00ED vzhledem k platn\u00FDm norm\u00E1m a vzhledem k nap\u011Bt\u00ED nav\u00FD\u0161en\u00ED potenci\u00E1lu stanice b\u011Bhem poruchy pro rozsah 300A a 800A, a tak\u00E9 bude posouzen vliv p\u0159izemn\u011Bn\u00ED posti\u017Een\u00E9 f\u00E1ze na \u00FArove\u0148 dotykov\u00E9ho nap\u011Bt\u00ED." . "11"^^ . "compensated network, ground fault, shunt, touch voltage, distribution transformer"@en . "Influence of Compensated Distribution Network Operation with Wide Range on a Touch Voltage"@en . . . "P\u0159\u00EDsp\u011Bvek je zam\u011B\u0159en na vyhodnocen\u00ED dotykov\u00E9ho nap\u011Bt\u00ED, kter\u00E9 bylo zaznamen\u00E1no b\u011Bhem s\u00E9rie experimen-t\u00E1ln\u00EDch m\u011B\u0159en\u00ED v kompenzovan\u00E9 distribu\u010Dn\u00ED soustav\u011B 22 kV, kter\u00E9 jsou vybaveny automatikou p\u0159izemn\u011Bn\u00ED posti\u017Een\u00E9 f\u00E1ze. B\u011Bhem experimentu bylo um\u011Ble vyvol\u00E1v\u00E1no kovov\u00E9 zemn\u00ED spojen\u00ED uvnit\u0159 vybran\u00FDch distri-bu\u010Dn\u00EDch trafostanic. Testov\u00E1ny byly dva rozsahy distribu\u010Dn\u00ED soustavy. Z\u00E1kladn\u00ED rozsah 300A, kter\u00FD je dle \u010Desk\u00FDch norem limitn\u00ED pro provoz sm\u00ED\u0161en\u00E9 DS a rozsah 800A, kter\u00FD je maxim\u00E1ln\u00ED rozsah testovan\u00E9 soustavy. V p\u0159\u00EDsp\u011Bvku bude zhodnocena \u00FArove\u0148 dotykov\u00E9ho nap\u011Bt\u00ED vzhledem k platn\u00FDm norm\u00E1m a vzhledem k nap\u011Bt\u00ED nav\u00FD\u0161en\u00ED potenci\u00E1lu stanice b\u011Bhem poruchy pro rozsah 300A a 800A, a tak\u00E9 bude posouzen vliv p\u0159izemn\u011Bn\u00ED posti\u017Een\u00E9 f\u00E1ze na \u00FArove\u0148 dotykov\u00E9ho nap\u011Bt\u00ED."@cs . "Topol\u00E1nek, David" . "RIV/00216305:26220/12:PU100660!RIV13-MSM-26220___" . . . "2012-11-06+01:00"^^ . "[4C99C996DCE2]" . . "Vliv provozov\u00E1n\u00ED kompenzovan\u00FDch s\u00EDt\u00ED velk\u00E9ho kapacitn\u00EDho rozsahu na velikost dotykov\u00FDch nap\u011Bt\u00ED"@cs . . . "P(EE2.3.30.0005)" . "Influence of Compensated Distribution Network Operation with Wide Range on a Touch Voltage"@en . . . "Toman, Petr" . . "Vliv provozov\u00E1n\u00ED kompenzovan\u00FDch s\u00EDt\u00ED velk\u00E9ho kapacitn\u00EDho rozsahu na velikost dotykov\u00FDch nap\u011Bt\u00ED" . "Vliv provozov\u00E1n\u00ED kompenzovan\u00FDch s\u00EDt\u00ED velk\u00E9ho kapacitn\u00EDho rozsahu na velikost dotykov\u00FDch nap\u011Bt\u00ED"@cs . "3"^^ . . . . "Dvo\u0159\u00E1k, Jarom\u00EDr" . "178086" . . "T\u00E1bor" . "Vliv provozov\u00E1n\u00ED kompenzovan\u00FDch s\u00EDt\u00ED velk\u00E9ho kapacitn\u00EDho rozsahu na velikost dotykov\u00FDch nap\u011Bt\u00ED" .