"\u017D\u00E1k, Jarom\u00EDr" . . . "Za\u0159\u00EDzen\u00ED pro stanoven\u00ED m\u00EDry dehydratace"@cs . "dehydration,WBAN,potassium,urea"@en . "Rozsah: 3 ~ 5000 mg(K+)/l Chyba m\u011B\u0159en\u00ED: <15% (v\u011Bt\u0161ina rozsahu <5%) P\u0159ipojen\u00ED k nad\u0159azen\u00E9mu syst\u00E9mu: ZigBee PRO Baterie: CR2477 (dle vyu\u017Eit\u00ED, min. 1 rok) Funk\u010Dn\u00ED vzorek byl vytvo\u0159en v r\u00E1mci evropsk\u00E9ho projektu MAS (AGREEMENT NUMBER - 120228) a v pr\u016Fb\u011Bhu ov\u011B\u0159ov\u00E1n\u00ED jeho \u010Dinnosti je vyu\u017E\u00EDv\u00E1n i pro m\u011B\u0159en\u00ED na pracovi\u0161ti \u0159e\u0161itele v Laborato\u0159i mikrosenzor\u016F a nanotechnologi\u00ED VUT v Brn\u011B (Technick\u00E1 10, N4.28)" . . "http://www.umel.feec.vutbr.cz/LabSensNano/products.aspx?id=36" . "Za\u0159\u00EDzen\u00ED pro stanoven\u00ED m\u00EDry dehydratace"@cs . . "Hub\u00E1lek, Jarom\u00EDr" . "Za\u0159\u00EDzen\u00ED pro stanoven\u00ED m\u00EDry dehydratace" . "26220" . . "4"^^ . "Za\u0159\u00EDzen\u00ED pro stanoven\u00ED m\u00EDry dehydratace" . . "Bu\u0161inov\u00E1, Petra" . "Kizek, Ren\u00E9" . "The device is used for long-term monitoring of organism dehydration state from urea sample. Hydration depends on pottasium ions concentration in urea which is measured. The device is constructed as mobile device for laboratory measurement and it is primarily used in connection to Wireless Body Area Network."@en . "4"^^ . . "[89771CB68352]" . . . . "Dehydration monitor"@en . . "Dehydration monitor"@en . "181903" . "Za\u0159\u00EDzen\u00ED slou\u017E\u00ED pro dlouhodob\u00E9 stanoven\u00ED m\u00EDry hydratace/dehydratace organismu ze vzorku mo\u010Di. \u00DArove\u0148 hydratace z\u00E1vis\u00ED na koncentraci drasl\u00EDkov\u00FDch iont\u016F, kter\u00E9 jsou za\u0159\u00EDzen\u00EDm detekov\u00E1ny. Za\u0159\u00EDzen\u00ED je konstruov\u00E1no pro laboratorn\u00ED m\u011B\u0159en\u00ED, je mobiln\u00ED a je prim\u00E1rn\u011B ur\u010Deno pro p\u0159ipojen\u00ED do bezdr\u00E1tov\u00E9 WBAN s\u00EDt\u011B (Wireless Body Area Network)."@cs . . . . "P(7H10021), P(ED2.1.00/03.0072)" . . "RIV/00216305:26220/12:PR26301!RIV13-MSM-26220___" . . . . . . "Za\u0159\u00EDzen\u00ED slou\u017E\u00ED pro dlouhodob\u00E9 stanoven\u00ED m\u00EDry hydratace/dehydratace organismu ze vzorku mo\u010Di. \u00DArove\u0148 hydratace z\u00E1vis\u00ED na koncentraci drasl\u00EDkov\u00FDch iont\u016F, kter\u00E9 jsou za\u0159\u00EDzen\u00EDm detekov\u00E1ny. Za\u0159\u00EDzen\u00ED je konstruov\u00E1no pro laboratorn\u00ED m\u011B\u0159en\u00ED, je mobiln\u00ED a je prim\u00E1rn\u011B ur\u010Deno pro p\u0159ipojen\u00ED do bezdr\u00E1tov\u00E9 WBAN s\u00EDt\u011B (Wireless Body Area Network)." . . "MAS Dehydration Sensor" . "RIV/00216305:26220/12:PR26301" . "N\u00E1klady na v\u00FDrobu cca 4000 K\u010D, n\u00E1klady na v\u00FDvoj 300 tis. K\u010D." . . . .