"RIV/00216305:26220/09:PU81389" . . "Z(MSM0021630516)" . . "Influence of Rotor Position on Oversaturated Areas Size of Induction Machine Magnetic Circuit"@en . . "3"^^ . . "RIV/00216305:26220/09:PU81389!RIV10-MSM-26220___" . . "3"^^ . . . . . "This article contains a solution of electromagnetic field distribution with oversaturated areas localization and description. The rotor position is important for the maximal magnetic circuit saturated identification and oversaturated areas size influence of magnetic circuit due to the variable magnetic resistance of path. Influence of rotor position on saturated magnetic circuit is analyzed with step on twenty angular rotations per rotor slot pitch. This analysis is done for 3-phase 1.1kW induction machine by finite element method. Also, the time behavior of magnetic flux density is analyzed in air gap for different load conditions of machine and general postprocessor results juxtaposition in conclusion."@en . "[9B738AF40604]" . "Skalka, Miroslav" . "319330" . "Influence of Rotor Position on Oversaturated Areas Size of Induction Machine Magnetic Circuit" . "Janda, Marcel" . "This article contains a solution of electromagnetic field distribution with oversaturated areas localization and description. The rotor position is important for the maximal magnetic circuit saturated identification and oversaturated areas size influence of magnetic circuit due to the variable magnetic resistance of path. Influence of rotor position on saturated magnetic circuit is analyzed with step on twenty angular rotations per rotor slot pitch. This analysis is done for 3-phase 1.1kW induction machine by finite element method. Also, the time behavior of magnetic flux density is analyzed in air gap for different load conditions of machine and general postprocessor results juxtaposition in conclusion." . "Zeszyty Problemowe - Maszyny Elektryczne" . . "84" . . . "0239-3646" . "26220" . "Influence of Rotor Position on Oversaturated Areas Size of Induction Machine Magnetic Circuit"@en . . . "Ondr\u016F\u0161ek, \u010Cestm\u00EDr" . "223"^^ . . "2009" . "PL - Polsk\u00E1 republika" . . "Influence of Rotor Position on Oversaturated Areas Size of Induction Machine Magnetic Circuit" . . . . "Magnetic Circuit, Magnetic Field, ANSYS, Finite Element Method, Induction Machine"@en .