. "2"^^ . "KR - Korejsk\u00E1 republika" . . . "Mi\u0161urec, Ji\u0159\u00ED" . . "Authentication and encryption algorithms of electrometer communication unit for remote data collection"@en . "RIV/00216305:26220/07:PU70116!RIV08-MSM-26220___" . "26220" . . . . "Autentiza\u010Dn\u00ED a \u0161ifrovac\u00ED algoritmy komunika\u010Dn\u00ED jednotky elektrom\u011Bru pro d\u00E1lkov\u00FD sb\u011Br dat"@cs . "data acquisiton, TCP IP, symmetric cryptosystem, AES encryption"@en . . "Authentication and encryption algorithms of electrometer communication unit for remote data collection" . . "141-150" . . . "Autentiza\u010Dn\u00ED a \u0161ifrovac\u00ED algoritmy komunika\u010Dn\u00ED jednotky elektrom\u011Bru pro d\u00E1lkov\u00FD sb\u011Br dat"@cs . "1" . . "[66F29C9AA6BC]" . "Koutn\u00FD, Martin" . . "Authentication and encryption algorithms of electrometer communication unit for remote data collection"@en . "P\u0159\u00EDsp\u011Bvek se zab\u00FDv\u00E1 n\u00E1vrhem a realizac\u00ED autentiza\u010Dn\u00EDch a \u0161ifrovac\u00EDch algoritm\u016F pro komunika\u010Dn\u00ED jednotku v s\u00EDti Internet. S\u00EDt\u011B TCP/IP jsou v sou\u010Dasnosti nejroz\u0161\u00ED\u0159en\u011Bj\u0161\u00ED s\u00EDt\u00ED slou\u017E\u00EDc\u00ED k datov\u00E9 komunikaci. Jednou z oblast\u00ED je i d\u00E1lkov\u00FD sb\u011Br dat v energetice, kdy se nap\u0159. ode\u010D\u00EDt\u00E1 spot\u0159eba elektrick\u00E9 energie p\u0159i tzv. pr\u016Fb\u011Bhov\u00E9m m\u011B\u0159en\u00ED. Zat\u00EDmco na stran\u011B sb\u011Brov\u00E9 telemetrick\u00E9 centr\u00E1ly, um\u00EDst\u011Bn\u00E9 v datov\u00E9m centru, je zabezpe\u010Den\u00ED v\u016F\u010Di \u00FAtok\u016Fm zven\u010D\u00ED \u0159e\u0161eno v r\u00E1mci distribu\u010Dn\u00ED spole\u010Dnosti, je situace na stran\u011B odb\u011Bratele elektrick\u00E9 energie naprosto odli\u0161n\u00E1. Komunika\u010Dn\u00ED jednotka elektrom\u011Bru je p\u0159ipojena zpravidla p\u0159\u00EDmo do s\u00EDt\u011B Internet. Vzhledem k tomu, \u017Ee hodnoty odb\u011Bru jsou obchodn\u011B citliv\u00E1 data a k jednotce sm\u00ED p\u0159istoupit pouze opr\u00E1vn\u011Bn\u00FD u\u017Eivatel je zapot\u0159eb\u00ED, aby ka\u017Ed\u00E1 jednotka obsahovala takov\u00E9 prvky, kter\u00E9 toto zabezpe\u010Den\u00ED zajist\u00ED."@cs . . "RIV/00216305:26220/07:PU70116" . . "411072" . "The paper deals with the design and implementation of authentication and encryption algorithms for the electrometer communication unit in the Internet network. Currently, the most widely used networks for data communication are TCP/IP networks. One of the application areas is the remote data control in power engineering, where the consumption of electric power is read in so-called continual metering. While in the telemetric acquisition station, located in the data centre, protection against attacks from the outside is dealt with within the framework of the distribution company, the situation at the electric power consumption end is quite different. The electrometer communication unit is usually connected directly to the Internet network. Since data on current consumption are commercially sensitive data and only a licensed user has access to the unit, it is necessary that every unit should include elements that will provide this protection."@en . "44" . "International Transaction on Computer Science and Engineering" . . . "Authentication and encryption algorithms of electrometer communication unit for remote data collection" . . "10"^^ . "P(1ET110530523), Z(MSM0021630513)" . "2"^^ . "The paper deals with the design and implementation of authentication and encryption algorithms for the electrometer communication unit in the Internet network. Currently, the most widely used networks for data communication are TCP/IP networks. One of the application areas is the remote data control in power engineering, where the consumption of electric power is read in so-called continual metering. While in the telemetric acquisition station, located in the data centre, protection against attacks from the outside is dealt with within the framework of the distribution company, the situation at the electric power consumption end is quite different. The electrometer communication unit is usually connected directly to the Internet network. Since data on current consumption are commercially sensitive data and only a licensed user has access to the unit, it is necessary that every unit should include elements that will provide this protection." . "1738-6438" . .