"26220" . . "Application of an adaptive semi-inversion neural controller for a laboratory hot-air system model is described. The system can be used to control two parameters \u2013 the airflow and the temperature inside the tunnel. The hot-air system displays negative effects commonly occurring in industrial applications \u2013 different static amplifications at different operating points, large offset increasing with time, dead zone and noise. The used semi-inversion neural controller is based on an inversion controller, but is capable of solving problems such as oscillating control action, noise sensitivity and ill-estimated parameters in the initial phase of control or adjustment."@en . . "Application of Neural Networks for Hot-Air System Control" . . . . "2004-03-25+01:00"^^ . . "Veleba, V\u00E1clav" . . "Proceedings of the WSEAS International Conferences NNA'04" . "Udine" . "Application of Neural Networks for Hot-Air System Control"@en . "Application of Neural Networks for Hot-Air System Control" . "Udine, It\u00E1lie" . . . "Application of Neural Networks for Hot-Air System Control"@en . . . "960-8052-96-3" . . "Semi-inversion controller, hot-air system, noise rejection, programmable logic controller, PID"@en . . . "RIV/00216305:26220/04:PU41334!RIV11-MSM-26220___" . . "WSEAS" . "1"^^ . . "RIV/00216305:26220/04:PU41334" . "555141" . . "[0B1269B23606]" . "1"^^ . "4"^^ . "Application of an adaptive semi-inversion neural controller for a laboratory hot-air system model is described. The system can be used to control two parameters \u2013 the airflow and the temperature inside the tunnel. The hot-air system displays negative effects commonly occurring in industrial applications \u2013 different static amplifications at different operating points, large offset increasing with time, dead zone and noise. The used semi-inversion neural controller is based on an inversion controller, but is capable of solving problems such as oscillating control action, noise sensitivity and ill-estimated parameters in the initial phase of control or adjustment." . . "P(GD102/03/H116), V, Z(MSM 260000013)" . . . .