. "Syst\u00E9m se skl\u00E1d\u00E1 z p\u0159\u00EDpravku, kter\u00FD je sestaven z vlastn\u00ED mechanick\u00E9 \u010D\u00E1sti, slou\u017E\u00EDc\u00ED pro definovan\u00E9 upnut\u00ED sn\u00EDma\u010D\u016F akustick\u00E9 emise. Sou\u010D\u00E1st\u00ED p\u0159\u00EDpravku je zku\u0161ebn\u00ED ty\u010D a Hsu-Nielsen\u016Fv zdroj ud\u00E1lost\u00ED AE. P\u0159\u00EDpravek je d\u00E1le dopln\u011Bn komer\u010Dn\u00EDm osciloskopem CleverScope a elektronickou vyhybkou pro nap\u00E1jen\u00ED sn\u00EDma\u010D\u016F s AE s p\u0159edzesilova\u010Dem. Pomoc\u00ED tohoto syst\u00E9mu jsou realizov\u00E1ny srovn\u00E1vac\u00ED zkou\u0161ky sn\u00EDma\u010D\u016F AE a tak je umo\u017En\u011Bno p\u0159i skupinov\u00FDch m\u011B\u0159en\u00EDch pou\u017E\u00EDvat sn\u00EDma\u010De s optim\u00E1ln\u00EDmi parametry."@cs . . "The system consists of the jig, which is built from mechanical part, used for the defined clamping of transducers of acoustic emission. Part of the product is the test-piece and Hsu-Nielsen source of AE events. The product is accompanied by a commercial osciloscope CleverScope and electronic separating filter for AE sensors with preamplifiers. With this system are made comparative tests of sensors for AE, and so it is possible to use the group measurements using the sensor with optimal parameters."@en . . . . "SSZCS 1" . "Syst\u00E9m pro srovn\u00E1vac\u00ED zkou\u0161ky citlivosti sn\u00EDma\u010D\u016F AE"@cs . "Syst\u00E9m se skl\u00E1d\u00E1 z p\u0159\u00EDpravku, kter\u00FD je sestaven z vlastn\u00ED mechanick\u00E9 \u010D\u00E1sti, slou\u017E\u00EDc\u00ED pro definovan\u00E9 upnut\u00ED sn\u00EDma\u010D\u016F akustick\u00E9 emise. Sou\u010D\u00E1st\u00ED p\u0159\u00EDpravku je zku\u0161ebn\u00ED ty\u010D a Hsu-Nielsen\u016Fv zdroj ud\u00E1lost\u00ED AE. P\u0159\u00EDpravek je d\u00E1le dopln\u011Bn komer\u010Dn\u00EDm osciloskopem CleverScope a elektronickou vyhybkou pro nap\u00E1jen\u00ED sn\u00EDma\u010D\u016F s AE s p\u0159edzesilova\u010Dem. Pomoc\u00ED tohoto syst\u00E9mu jsou realizov\u00E1ny srovn\u00E1vac\u00ED zkou\u0161ky sn\u00EDma\u010D\u016F AE a tak je umo\u017En\u011Bno p\u0159i skupinov\u00FDch m\u011B\u0159en\u00EDch pou\u017E\u00EDvat sn\u00EDma\u010De s optim\u00E1ln\u00EDmi parametry." . . . . "RIV/00216305:26210/11:PR25575" . "P(ED0002/01/01), P(FR-TI1/371)" . "Syst\u00E9m pro srovn\u00E1vac\u00ED zkou\u0161ky citlivosti sn\u00EDma\u010D\u016F AE"@cs . "VUT FSI, Technick\u00E1 2, Brno, budova A3, laborato\u0159 109" . . "26210" . "1"^^ . . "http://www.uk.fme.vutbr.cz/projekty/seznam/" . "1"^^ . "234041" . "Syst\u00E9m pro srovn\u00E1vac\u00ED zkou\u0161ky citlivosti sn\u00EDma\u010D\u016F AE" . "acoustic emission, sensor, sensitivity, AE event"@en . "[D63C357664C2]" . . . "Syst\u00E9m umo\u017En\u00ED kvalitn\u011Bj\u0161\u00ED realizaci v\u00FDzkumn\u00FDch a komer\u010Dn\u00EDch \u00FAloh, realizovan\u00FDch na pracovi\u0161ti. Bude mo\u017En\u00E9 vyu\u017E\u00EDt i star\u0161\u00ED sn\u00EDma\u010De akustick\u00E9 emise, kter\u00E9 ji\u017E p\u0159ekro\u010Dily stanovenou \u017Eivotnost, nicm\u00E9n\u011B jejich parametry st\u00E1le vyhovuj\u00ED po\u017Eadavk\u016Fm zkou\u0161ek." . "Mazal, Pavel" . . "Syst\u00E9m pro srovn\u00E1vac\u00ED zkou\u0161ky citlivosti sn\u00EDma\u010D\u016F AE" . "Funk\u010Dn\u00ED vzorek byl vyvinut v laborato\u0159i akustick\u00E9 emise \u00DAstavu konstruov\u00E1n\u00ED v r\u00E1mci \u0159e\u0161en\u00ED v\u00FDzkumn\u00FDch projekt\u016F a slou\u017E\u00ED zejm\u00E9na pro zabezpe\u010Den\u00ED pot\u0159eb jej\u00EDho provozu. Aktu\u00E1ln\u00ED konstrukce je ur\u010Dena p\u0159edev\u0161\u00EDm pro v\u00E1lcov\u00E9 sn\u00EDma\u010De s pr\u016Fm\u011Brem up\u00EDnac\u00ED \u010D\u00E1sti cca 25 mm. Vyu\u017Eit\u00ED je mo\u017En\u00E9 i pro p\u0159\u00EDpadn\u00E9 dal\u0161\u00ED extern\u00ED z\u00E1jemce. Funk\u010Dn\u00ED vzorek je \u010D\u00E1ste\u010Dn\u011B sou\u010D\u00E1st\u00ED \u0159e\u0161en\u00ED projektu MPO TIP, jeho\u017E \u0159e\u0161itelem je firma ZD Rpety se s\u00EDdlem ve Retech - DI\u010C CZ00103063. Smlouva \u010D.FR-TI1/371 byla s firmou uzav\u0159ena dne 7.10.2009." . . . . "RIV/00216305:26210/11:PR25575!RIV12-MSM-26210___" . . "System for the comparative tests of sensitivity of AE sensors"@en . . . "System for the comparative tests of sensitivity of AE sensors"@en . . .