. "OT02/LPTP/0908" . "Kotrb\u00E1\u010Dek, Petr" . . "[14F0151F0602]" . . . "U.S.Steel Ko\u0161ice, s.r.o." . . . "26210" . . "Zv\u00FD\u0161en\u00ED \u00FA\u010Dinnosti chlazen\u00ED pracovn\u00EDch v\u00E1lc\u016F na studen\u00E9 v\u00E1lcovn\u011B Midwest , U.Steel Ko\u0161ice"@cs . "Cooling system for cold rolling plant at Midwest, U.S. Steel Ko\u0161ice"@en . . "5"^^ . "5"^^ . "cooling system, cold rolling"@en . "The cooling collectors were designed based on a series of laboratory tests using various types of cooling nozzles and different cooling configurations as well. The collectors were built in at hot rolling mill in U.S.Steel Midwest where are used now."@en . . . "N" . . "N\u00E1vrh kolektor\u016F pro chlazen\u00ED v\u00E1lc\u016F pro v\u00E1lcov\u00E1n\u00ED za studena. N\u00E1vrh byl zpracov\u00E1n na z\u00E1klad\u011B laboratorn\u00EDch test\u016F s vyu\u017Eit\u00EDm r\u016Fzn\u00FDch druh\u016F chladic\u00EDch trysek a r\u016Fzn\u00FDch konfigurac\u00ED chlazen\u00ED. Kolektory byly postaveny a jsou pou\u017E\u00EDv\u00E1ny na v\u00E1lcovn\u011B za studena trati v US Steel Midwest."@cs . "Pohanka, Michal" . . . "RIV/00216305:26210/08:PR23568!RIV10-MSM-26210___" . . "Raudensk\u00FD, Miroslav" . "Cooling system for cold rolling plant at Midwest, U.S. Steel Ko\u0161ice"@en . "N\u00E1vrh kolektor\u016F pro chlazen\u00ED v\u00E1lc\u016F pro v\u00E1lcov\u00E1n\u00ED za studena. N\u00E1vrh byl zpracov\u00E1n na z\u00E1klad\u011B laboratorn\u00EDch test\u016F s vyu\u017Eit\u00EDm r\u016Fzn\u00FDch druh\u016F chladic\u00EDch trysek a r\u016Fzn\u00FDch konfigurac\u00ED chlazen\u00ED. Kolektory byly postaveny a jsou pou\u017E\u00EDv\u00E1ny na v\u00E1lcovn\u011B za studena trati v US Steel Midwest." . "Zv\u00FD\u0161en\u00ED \u00FA\u010Dinnosti chlazen\u00ED pracovn\u00EDch v\u00E1lc\u016F na studen\u00E9 v\u00E1lcovn\u011B Midwest , U.Steel Ko\u0161ice" . "Hn\u00EDzdil, Milan" . . "Horsk\u00FD, Jaroslav" . . . "RIV/00216305:26210/08:PR23568" . . . "Zv\u00FD\u0161en\u00ED \u00FA\u010Dinnosti chlazen\u00ED pracovn\u00EDch v\u00E1lc\u016F na studen\u00E9 v\u00E1lcovn\u011B Midwest , U.Steel Ko\u0161ice" . "Ekonomick\u00E9 parametry vych\u00E1z\u00ED z n\u00E1r\u016Fstu kvality v\u00FDvalk\u016F po p\u0159estavb\u011B chlazen\u00ED. Z pozorovan\u00E9ho sn\u00ED\u017Een\u00ED vlnitosti v pr\u016Fm\u011Bru o 3% je mo\u017Eno odvodit odhad ekonomick\u00FDch p\u0159\u00EDnos\u016F." . . "Zv\u00FD\u0161en\u00ED \u00FA\u010Dinnosti chlazen\u00ED pracovn\u00EDch v\u00E1lc\u016F na studen\u00E9 v\u00E1lcovn\u011B Midwest , U.Steel Ko\u0161ice"@cs . . "407431" . "Kolektory umo\u017E\u0148uj\u00ED dosa\u017Een\u00ED homogenn\u00EDho chlazen\u00ED s pr\u016Fm\u011Brnou intenzitou p\u0159estupu tepla 28 kW/m2K. N\u00E1vrh umo\u017E\u0148uje sek\u010Dn\u00ED \u0159\u00EDzen\u00ED teploty v\u00E1lc\u016F vyp\u00EDn\u00E1n\u00EDm \u010D\u00E1st\u00ED kolektor\u016F pro USS Midwest - subjekt U.S.Steel Ko\u0161ice s.r.o., I\u010C: 36" .