"2"^^ . . "Hor\u00E1k, Petr" . "Vysok\u00E9 u\u010Den\u00ED technick\u00E9 v Brn\u011B. Fakulta stavebn\u00ED" . . "2"^^ . "Evaluation of three rooms linear model"@en . "[053BC8C107F6]" . . "236"^^ . "2014-02-14+01:00"^^ . "54423" . . "978-80-214-4864-3" . . "During the heating and cooling of rooms the relationship between rooms is necessary. Temperature process may in some cases be different. This phenomenon occurs in the rooms with a different number of cooled constructions."@en . . "Workshop 3 \u2013 Praktick\u00E9 zku\u0161enosti z realizace TZB soustav a staveb, Projekt OKTAEDR \u2013 partnerstv\u00ED a s\u00EDt\u011B ve stavebnictv\u00ED" . "Vyhodnocen\u00ED line\u00E1rn\u00EDho modelu t\u0159\u00ED m\u00EDstnost\u00ED"@cs . "RIV/00216305:26110/14:PU107467" . . "P\u0159i \u0159e\u0161en\u00ED oh\u0159evu a chladnut\u00ED m\u00EDstnost\u00ED je nutno \u0159e\u0161it vztah dan\u00E9 m\u00EDstnosti k m\u00EDstnostem soused\u00EDc\u00EDm. Pr\u016Fb\u011Bh teplot m\u016F\u017Ee b\u00FDt v n\u011Bkter\u00FDch p\u0159\u00EDpadech odli\u0161n\u00FD. Tento jev nastane, kdy\u017E maj\u00ED m\u00EDstnosti r\u016Fzn\u00FD po\u010Det ochlazovan\u00FDch konstrukc\u00ED. Soused\u00ED-li m\u00EDstnosti s r\u016Fzn\u00FDm pr\u016Fb\u011Bhem teploty vzduchu, proud\u00ED pak d\u011Bl\u00EDc\u00ED konstrukc\u00ED tepeln\u00FD tok z m\u00EDstnosti o vy\u0161\u0161\u00ED teplot\u011B vzduchu do m\u00EDstnosti s ni\u017E\u0161\u00ED teplotou vzduchu. T\u00EDmto se ovliv\u0148uje tepeln\u00E1 bilance obou m\u00EDstnost\u00ED."@cs . "Vyhodnocen\u00ED line\u00E1rn\u00EDho modelu t\u0159\u00ED m\u00EDstnost\u00ED"@cs . . . . "Evaluation of three rooms linear model"@en . "Vyhodnocen\u00ED line\u00E1rn\u00EDho modelu t\u0159\u00ED m\u00EDstnost\u00ED" . "Brno" . "Vyhodnocen\u00ED line\u00E1rn\u00EDho modelu t\u0159\u00ED m\u00EDstnost\u00ED" . "Brno" . . . "Ambro\u017Eov\u00E1, Iva" . . "P\u0159i \u0159e\u0161en\u00ED oh\u0159evu a chladnut\u00ED m\u00EDstnost\u00ED je nutno \u0159e\u0161it vztah dan\u00E9 m\u00EDstnosti k m\u00EDstnostem soused\u00EDc\u00EDm. Pr\u016Fb\u011Bh teplot m\u016F\u017Ee b\u00FDt v n\u011Bkter\u00FDch p\u0159\u00EDpadech odli\u0161n\u00FD. Tento jev nastane, kdy\u017E maj\u00ED m\u00EDstnosti r\u016Fzn\u00FD po\u010Det ochlazovan\u00FDch konstrukc\u00ED. Soused\u00ED-li m\u00EDstnosti s r\u016Fzn\u00FDm pr\u016Fb\u011Bhem teploty vzduchu, proud\u00ED pak d\u011Bl\u00EDc\u00ED konstrukc\u00ED tepeln\u00FD tok z m\u00EDstnosti o vy\u0161\u0161\u00ED teplot\u011B vzduchu do m\u00EDstnosti s ni\u017E\u0161\u00ED teplotou vzduchu. T\u00EDmto se ovliv\u0148uje tepeln\u00E1 bilance obou m\u00EDstnost\u00ED." . . "26110" . . . "S" . "RIV/00216305:26110/14:PU107467!RIV15-MSM-26110___" . "heat transfer, thermal balance, linear room system"@en .