"RIV/00216305:26110/14:PU105685" . "899" . "The transition of the water steam through the composition of the diffusive closed circumferential wall of the wooden house with the proper and improper realization of vapor barrier"@en . "4"^^ . "The research is focused on measuring of the diffusion of moisture by composition of the diffusive closed circumferential wall of the wooden house with the proper and improper realization of the vapor barrier. To perform this research the experimental wooden house EXDR1 is going to be used. The wall, which would be the validation of measurement, is designed as a closed diffusion. The aim of this research is to compare the measurement results. The measured values of humidity probes are going to be used for the comparison. These probes are going to be located in place of a wooden post and in the field between the posts and the temperature-humidity sensors that are going to be installed only in the field between the posts. Thus, placing the probes to measure humidity of wooden post and the temperature-humidity sensors are going to measure the humidity and the temperature of with the proper and improper realization of vapor barrier (foil) for interior moisture to simulate processes normally happening insi" . . . "The transition of the water steam through the composition of the diffusive closed circumferential wall of the wooden house with the proper and improper realization of vapor barrier" . "S" . "51048" . "2014" . "The transition of the water steam through the composition of the diffusive closed circumferential wall of the wooden house with the proper and improper realization of vapor barrier"@en . . "Advanced Materials Research" . . . . "CH - \u0160v\u00FDcarsk\u00E1 konfederace" . "The transition of the water steam through the composition of the diffusive closed circumferential wall of the wooden house with the proper and improper realization of vapor barrier" . . . . . . . "Uvizlov\u00E1, Martina" . "1022-6680" . . . . "[85707273DFF4]" . "The transition of the water steam, the diffusive closed circumferential wall, the vapor barrier, the humidity probe, the temperature-humidity sensor"@en . "RIV/00216305:26110/14:PU105685!RIV15-MSM-26110___" . . "Be\u010Dkovsk\u00E1, Tereza" . "2"^^ . . "The research is focused on measuring of the diffusion of moisture by composition of the diffusive closed circumferential wall of the wooden house with the proper and improper realization of the vapor barrier. To perform this research the experimental wooden house EXDR1 is going to be used. The wall, which would be the validation of measurement, is designed as a closed diffusion. The aim of this research is to compare the measurement results. The measured values of humidity probes are going to be used for the comparison. These probes are going to be located in place of a wooden post and in the field between the posts and the temperature-humidity sensors that are going to be installed only in the field between the posts. Thus, placing the probes to measure humidity of wooden post and the temperature-humidity sensors are going to measure the humidity and the temperature of with the proper and improper realization of vapor barrier (foil) for interior moisture to simulate processes normally happening insi"@en . "26110" . "2"^^ .