"000340082600004" . . "Central European Journal of Energetic Materials" . . "impact; gap test; CL-20; 12-hexaazaisowurtzitane; 10; 8; 6; 4; 12-hexanitro-2; 10; 8; 6; 4; epsilon-2; RDX; beta-HMX; BCHMX"@en . . . "PL - Polsk\u00E1 republika" . "Concerning the Shock Sensitivity of Cyclic Nitramines Incorporated into a Polyisobutylene Matrix" . . "Pelik\u00E1n, Vojt\u011Bch" . "Elbeih, Ahmed Ikhlas Mohamed" . . "I, S" . "Zeman, Svatopluk" . "Yan, Qi Long" . "RIV/00216275:25310/14:39898595" . "RIV/00216275:25310/14:39898595!RIV15-MSM-25310___" . "Elbeih, Ahmed Ikhlas Mohamed" . "Two types of plastic bonded explosives (PBXs) based on e-2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (e-HNIW, CL-20), and PBXs based on 1,3,5-trinitro-1,3,5-triazinane (RDX), b-1,3,4,7-tetranitro-1,3,5,7-tetrazocane (b-HMX) and cis-1,3,4,6-tetranitro-octahydroimidazo-[4,5-d]imidazole (bicyclo-HMX, BCHMX) were prepd. using a polyisobutylene binder, i.e. a C4 matrix. One version of the e-HNIW PBX is a product with reduced sensitivity (RS-e-HNIW). All these PBXs were tested using the Small Scale Gap Test according to STANAG 4488. The results on the PBXs with RDX, b-HMX and BCHMX correspond to the impact sensitivities of the original cryst. nitramines. This is not entirely valid for e-HNIW. In other words, PBXs with RS-e-HNIW cannot achieve as low a shock sensitivity as would be expected from the differences obtained from the impact sensitivities between RDX, b-HMX and BCHMX, on the one hand, and RS-e-HNIW on the other. It is shown that the morphological stability of RS-e-HNIW in the C4 matrix is insufficient." . "2" . . . "8557" . "11" . . . "[C21D07FCE7CB]" . . "25310" . . . . "17"^^ . . . . . "Concerning the Shock Sensitivity of Cyclic Nitramines Incorporated into a Polyisobutylene Matrix" . "Concerning the Shock Sensitivity of Cyclic Nitramines Incorporated into a Polyisobutylene Matrix"@en . . . "Yan, Qi Long" . . "Erben, Milan" . . "5"^^ . . . "Concerning the Shock Sensitivity of Cyclic Nitramines Incorporated into a Polyisobutylene Matrix"@en . . "Two types of plastic bonded explosives (PBXs) based on e-2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (e-HNIW, CL-20), and PBXs based on 1,3,5-trinitro-1,3,5-triazinane (RDX), b-1,3,4,7-tetranitro-1,3,5,7-tetrazocane (b-HMX) and cis-1,3,4,6-tetranitro-octahydroimidazo-[4,5-d]imidazole (bicyclo-HMX, BCHMX) were prepd. using a polyisobutylene binder, i.e. a C4 matrix. One version of the e-HNIW PBX is a product with reduced sensitivity (RS-e-HNIW). All these PBXs were tested using the Small Scale Gap Test according to STANAG 4488. The results on the PBXs with RDX, b-HMX and BCHMX correspond to the impact sensitivities of the original cryst. nitramines. This is not entirely valid for e-HNIW. In other words, PBXs with RS-e-HNIW cannot achieve as low a shock sensitivity as would be expected from the differences obtained from the impact sensitivities between RDX, b-HMX and BCHMX, on the one hand, and RS-e-HNIW on the other. It is shown that the morphological stability of RS-e-HNIW in the C4 matrix is insufficient."@en . . "6"^^ . . "1733-7178" . "Akstein, Zbynek" .