"Z(MSM0021627502)" . "N" . . . . "\u0160i\u0161ka, Bed\u0159ich" . "517019" . "The Dead-end Hollow Fibre Microfiltration Module Testing"@en . "4"^^ . . "CZ - \u010Cesk\u00E1 republika" . "209-219" . . . . "[9D166C6FED8E]" . "11" . "The Dead-end Hollow Fibre Microfiltration Module Testing"@en . "25310" . "hollow fiber module; microfiltration; membrane fouling; mathematical model"@en . . "Dole\u010Dek, Petr" . . "In this work, the hollow fibre membrane module designed for dead-end operations was tested. The hollow fibre cartridge operated from the outside to the inside during a filtration process, the membrane used was the polypropylene microfiltration membrane. Process characteristic measurements were carried out based on the pure water flux measurements. Next, the set of experiments dealing with microfiltration of model solutions was performed at different conditions. The influence of process parameters on the permeate flux was studied aimed mainly at the membrane fouling preclusion. The set of experiments for ?sustainable? flux determination was performed for water suspension of A-zeolite. From the results it followed that the fouling of the membrane was negligible for concentration of zeolite less than 3 kg.m-3. A simple mathematical model of the process was suggested and experimentally verified."@en . "Testov\u00E1n\u00ED mikrofiltra\u010Dn\u00EDho za\u0159\u00EDzen\u00ED s modulem s dut\u00FDmi vl\u00E1kny"@cs . "1211-5541" . . . . "In this work, the hollow fibre membrane module designed for dead-end operations was tested. The hollow fibre cartridge operated from the outside to the inside during a filtration process, the membrane used was the polypropylene microfiltration membrane. Process characteristic measurements were carried out based on the pure water flux measurements. Next, the set of experiments dealing with microfiltration of model solutions was performed at different conditions. The influence of process parameters on the permeate flux was studied aimed mainly at the membrane fouling preclusion. The set of experiments for ?sustainable? flux determination was performed for water suspension of A-zeolite. From the results it followed that the fouling of the membrane was negligible for concentration of zeolite less than 3 kg.m-3. A simple mathematical model of the process was suggested and experimentally verified." . . "Cakl, Ji\u0159\u00ED" . "P\u0159edm\u011Btem t\u00E9to pr\u00E1ce bylo sestaven\u00ED a ov\u011B\u0159en\u00ED funkce dead-end mikrofiltra\u010Dn\u00EDho modulu s dut\u00FDmi vl\u00E1kny. Membr\u00E1nov\u00E1 jednotka pracovala v outside-in uspo\u0159\u00E1d\u00E1n\u00ED, membr\u00E1na byla tvo\u0159ena svazkem polypropylenov\u00FDch dut\u00FDch vl\u00E1ken. C\u00EDlem experiment\u016F bylo prom\u011B\u0159en\u00ED n\u011Bkter\u00FDch procesn\u00EDch charakteristik p\u0159i pr\u016Ftoku \u010Dist\u00E9 vody membr\u00E1novou jednotkou a p\u0159edev\u0161\u00EDm pak studium zan\u00E1\u0161en\u00ED vl\u00E1ken p\u0159i vlastn\u00ED mikrofiltraci vodn\u00FDch suspenz\u00ED zeolitu. Z v\u00FDsledk\u016F experiment\u016F vyplynulo, \u017Ee p\u0159i ni\u017E\u0161\u00EDch koncentrac\u00EDch zeolitu bylo zan\u00E1\u0161en\u00ED membr\u00E1ny prakticky zanedbateln\u00E9. V z\u00E1v\u011Bru byl navr\u017Een a experiment\u00E1ln\u011B ov\u011B\u0159en jednoduch\u00FD matematick\u00FD model procesu."@cs . "Jir\u00E1nkov\u00E1, Hana" . . . "Testov\u00E1n\u00ED mikrofiltra\u010Dn\u00EDho za\u0159\u00EDzen\u00ED s modulem s dut\u00FDmi vl\u00E1kny"@cs . "Scientific Papers of the University of Pardubice, Series A, Faculty of Chemical Technology" . . "RIV/00216275:25310/05:00002806!RIV08-MSM-25310___" . . "The Dead-end Hollow Fibre Microfiltration Module Testing" . . "The Dead-end Hollow Fibre Microfiltration Module Testing" . "RIV/00216275:25310/05:00002806" . "11"^^ . . "4"^^ .